{"id":18453,"date":"2025-03-19T11:27:11","date_gmt":"2025-03-19T10:27:11","guid":{"rendered":"https:\/\/www.orteanext.com\/case-histories\/transformateur-disolement-pour-installation-dans-un-environnement-tres-chaud\/"},"modified":"2025-12-10T17:14:20","modified_gmt":"2025-12-10T16:14:20","slug":"transformador-de-aislamiento-para-instalacion-en-ambiente-muy-caluroso","status":"publish","type":"case","link":"https:\/\/www.orteanext.com\/es\/case-histories\/transformador-de-aislamiento-para-instalacion-en-ambiente-muy-caluroso\/","title":{"rendered":"TRANSFORMADOR DE AISLAMIENTO PARA INSTALACI\u00d3N EN AMBIENTE MUY CALUROSO"},"content":{"rendered":"<h3>EL CLIENTE<\/h3>\n<p>Una gran empresa mec\u00e1nica del norte de Italia especializada en la fabricaci\u00f3n de taladradoras y fresadoras.<\/p>\n<h3>LA NECESIDAD<\/h3>\n<p>En las empresas \u00e1vidas de energ\u00eda, caracterizadas por un elevado consumo energ\u00e9tico, la tensi\u00f3n de alimentaci\u00f3n suele aumentarse a 500 V, reduciendo as\u00ed la corriente absorbida para la misma potencia y permitiendo el uso de cables de alimentaci\u00f3n m\u00e1s peque\u00f1os con el consiguiente ahorro de costes.<\/p>\n<p>Sin embargo, los equipos en funcionamiento requieren una tensi\u00f3n de 400 V, por lo que resulta esencial utilizar transformadores reductores que no s\u00f3lo garanticen el aislamiento galv\u00e1nico, sino que tambi\u00e9n reduzcan la tensi\u00f3n de 500 V a 400 V de forma segura y eficiente.<\/p>\n<h3>NUESTRA SOLUCI\u00d3N<\/h3>\n<p>El transformador reductor de potencia deb\u00eda instalarse en un entorno especialmente caluroso.<\/p>\n<p>Para garantizar un rendimiento y una seguridad de funcionamiento \u00f3ptimos, los ingenieros de Ortea desarrollaron una soluci\u00f3n a medida, dise\u00f1ando una carcasa de armario equipada con un sistema de refrigeraci\u00f3n mediante acondicionadores de aire.<\/p>\n<p>Adem\u00e1s, para garantizar una integraci\u00f3n segura y pr\u00e1ctica, el armario el\u00e9ctrico se complet\u00f3 con la instalaci\u00f3n de interruptores de entrada y salida.<\/p>\n<p>Ortea es capaz de satisfacer los requisitos m\u00e1s espec\u00edficos gracias a su experiencia en la personalizaci\u00f3n de soluciones, ofreciendo una tecnolog\u00eda fiable y de alto rendimiento.<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/www.orteanext.com\/es\/transformadores-y-reactores-de-bt\/soluciones-a-medida-el-transformador-de-aislamiento-adecuado-para-cada-necesidad\/\"><strong>Descubrir el art\u00edculo relacionado<\/strong><\/a><\/p>\n","protected":false},"featured_media":18443,"template":"","sector":[24302],"tech":[24320],"class_list":["post-18453","case","type-case","status-publish","has-post-thumbnail","hentry","sector-industria-es","tech-transformadores-reactores"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Transformador de aislamiento con acondicionadores de aire<\/title>\n<meta name=\"description\" content=\"Transformador de potencia reductor (500-400 V) alojado en cabina con acondicionadores de aire para instalaci\u00f3n en ambiente muy caluroso.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.orteanext.com\/es\/case-histories\/transformador-de-aislamiento-para-instalacion-en-ambiente-muy-caluroso\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Transformador de aislamiento con acondicionadores de aire\" \/>\n<meta property=\"og:description\" content=\"Transformador de potencia reductor (500-400 V) alojado en cabina con acondicionadores de aire para instalaci\u00f3n en ambiente muy caluroso.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.orteanext.com\/es\/case-histories\/transformador-de-aislamiento-para-instalacion-en-ambiente-muy-caluroso\/\" \/>\n<meta property=\"og:site_name\" content=\"Ortea Next\" \/>\n<meta property=\"article:modified_time\" content=\"2025-12-10T16:14:20+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.orteanext.com\/wp-content\/uploads\/2025\/03\/P15.1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"580\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/es\\\/case-histories\\\/transformador-de-aislamiento-para-instalacion-en-ambiente-muy-caluroso\\\/\",\"url\":\"https:\\\/\\\/www.orteanext.com\\\/es\\\/case-histories\\\/transformador-de-aislamiento-para-instalacion-en-ambiente-muy-caluroso\\\/\",\"name\":\"Transformador de aislamiento con acondicionadores de aire\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/es\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/es\\\/case-histories\\\/transformador-de-aislamiento-para-instalacion-en-ambiente-muy-caluroso\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/es\\\/case-histories\\\/transformador-de-aislamiento-para-instalacion-en-ambiente-muy-caluroso\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.orteanext.com\\\/wp-content\\\/uploads\\\/2025\\\/03\\\/P15.1.jpg\",\"datePublished\":\"2025-03-19T10:27:11+00:00\",\"dateModified\":\"2025-12-10T16:14:20+00:00\",\"description\":\"Transformador de potencia reductor (500-400 V) alojado en cabina con acondicionadores de aire para instalaci\u00f3n en ambiente muy caluroso.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/es\\\/case-histories\\\/transformador-de-aislamiento-para-instalacion-en-ambiente-muy-caluroso\\\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.orteanext.com\\\/es\\\/case-histories\\\/transformador-de-aislamiento-para-instalacion-en-ambiente-muy-caluroso\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/es\\\/case-histories\\\/transformador-de-aislamiento-para-instalacion-en-ambiente-muy-caluroso\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.orteanext.com\\\/wp-content\\\/uploads\\\/2025\\\/03\\\/P15.1.jpg\",\"contentUrl\":\"https:\\\/\\\/www.orteanext.com\\\/wp-content\\\/uploads\\\/2025\\\/03\\\/P15.1.jpg\",\"width\":800,\"height\":580},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/es\\\/case-histories\\\/transformador-de-aislamiento-para-instalacion-en-ambiente-muy-caluroso\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.orteanext.com\\\/es\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Case Histories\",\"item\":\"https:\\\/\\\/www.orteanext.com\\\/es\\\/case-histories\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"TRANSFORMADOR DE AISLAMIENTO PARA INSTALACI\u00d3N EN AMBIENTE MUY CALUROSO\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/es\\\/#website\",\"url\":\"https:\\\/\\\/www.orteanext.com\\\/es\\\/\",\"name\":\"Ortea Next\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/es\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.orteanext.com\\\/es\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/es\\\/#organization\",\"name\":\"Ortea SpA\",\"url\":\"https:\\\/\\\/www.orteanext.com\\\/es\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/es\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.orteanext.com\\\/wp-content\\\/uploads\\\/2022\\\/05\\\/logo_ortea.svg\",\"contentUrl\":\"https:\\\/\\\/www.orteanext.com\\\/wp-content\\\/uploads\\\/2022\\\/05\\\/logo_ortea.svg\",\"width\":1,\"height\":1,\"caption\":\"Ortea SpA\"},\"image\":{\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/es\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/ortea\\\/\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCqwcSga4ZzG3ntf6hYRu_Nw?reload=9\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Transformador de aislamiento con acondicionadores de aire","description":"Transformador de potencia reductor (500-400 V) alojado en cabina con acondicionadores de aire para instalaci\u00f3n en ambiente muy caluroso.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.orteanext.com\/es\/case-histories\/transformador-de-aislamiento-para-instalacion-en-ambiente-muy-caluroso\/","og_locale":"es_ES","og_type":"article","og_title":"Transformador de aislamiento con acondicionadores de aire","og_description":"Transformador de potencia reductor (500-400 V) alojado en cabina con acondicionadores de aire para instalaci\u00f3n en ambiente muy caluroso.","og_url":"https:\/\/www.orteanext.com\/es\/case-histories\/transformador-de-aislamiento-para-instalacion-en-ambiente-muy-caluroso\/","og_site_name":"Ortea Next","article_modified_time":"2025-12-10T16:14:20+00:00","og_image":[{"width":800,"height":580,"url":"https:\/\/www.orteanext.com\/wp-content\/uploads\/2025\/03\/P15.1.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Tiempo de lectura":"2 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.orteanext.com\/es\/case-histories\/transformador-de-aislamiento-para-instalacion-en-ambiente-muy-caluroso\/","url":"https:\/\/www.orteanext.com\/es\/case-histories\/transformador-de-aislamiento-para-instalacion-en-ambiente-muy-caluroso\/","name":"Transformador de aislamiento con acondicionadores de aire","isPartOf":{"@id":"https:\/\/www.orteanext.com\/es\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.orteanext.com\/es\/case-histories\/transformador-de-aislamiento-para-instalacion-en-ambiente-muy-caluroso\/#primaryimage"},"image":{"@id":"https:\/\/www.orteanext.com\/es\/case-histories\/transformador-de-aislamiento-para-instalacion-en-ambiente-muy-caluroso\/#primaryimage"},"thumbnailUrl":"https:\/\/www.orteanext.com\/wp-content\/uploads\/2025\/03\/P15.1.jpg","datePublished":"2025-03-19T10:27:11+00:00","dateModified":"2025-12-10T16:14:20+00:00","description":"Transformador de potencia reductor (500-400 V) alojado en cabina con acondicionadores de aire para instalaci\u00f3n en ambiente muy caluroso.","breadcrumb":{"@id":"https:\/\/www.orteanext.com\/es\/case-histories\/transformador-de-aislamiento-para-instalacion-en-ambiente-muy-caluroso\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.orteanext.com\/es\/case-histories\/transformador-de-aislamiento-para-instalacion-en-ambiente-muy-caluroso\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.orteanext.com\/es\/case-histories\/transformador-de-aislamiento-para-instalacion-en-ambiente-muy-caluroso\/#primaryimage","url":"https:\/\/www.orteanext.com\/wp-content\/uploads\/2025\/03\/P15.1.jpg","contentUrl":"https:\/\/www.orteanext.com\/wp-content\/uploads\/2025\/03\/P15.1.jpg","width":800,"height":580},{"@type":"BreadcrumbList","@id":"https:\/\/www.orteanext.com\/es\/case-histories\/transformador-de-aislamiento-para-instalacion-en-ambiente-muy-caluroso\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.orteanext.com\/es\/"},{"@type":"ListItem","position":2,"name":"Case Histories","item":"https:\/\/www.orteanext.com\/es\/case-histories\/"},{"@type":"ListItem","position":3,"name":"TRANSFORMADOR DE AISLAMIENTO PARA INSTALACI\u00d3N EN AMBIENTE MUY CALUROSO"}]},{"@type":"WebSite","@id":"https:\/\/www.orteanext.com\/es\/#website","url":"https:\/\/www.orteanext.com\/es\/","name":"Ortea Next","description":"","publisher":{"@id":"https:\/\/www.orteanext.com\/es\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.orteanext.com\/es\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/www.orteanext.com\/es\/#organization","name":"Ortea SpA","url":"https:\/\/www.orteanext.com\/es\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.orteanext.com\/es\/#\/schema\/logo\/image\/","url":"https:\/\/www.orteanext.com\/wp-content\/uploads\/2022\/05\/logo_ortea.svg","contentUrl":"https:\/\/www.orteanext.com\/wp-content\/uploads\/2022\/05\/logo_ortea.svg","width":1,"height":1,"caption":"Ortea SpA"},"image":{"@id":"https:\/\/www.orteanext.com\/es\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/ortea\/","https:\/\/www.youtube.com\/channel\/UCqwcSga4ZzG3ntf6hYRu_Nw?reload=9"]}]}},"_links":{"self":[{"href":"https:\/\/www.orteanext.com\/es\/wp-json\/wp\/v2\/case\/18453","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.orteanext.com\/es\/wp-json\/wp\/v2\/case"}],"about":[{"href":"https:\/\/www.orteanext.com\/es\/wp-json\/wp\/v2\/types\/case"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.orteanext.com\/es\/wp-json\/wp\/v2\/media\/18443"}],"wp:attachment":[{"href":"https:\/\/www.orteanext.com\/es\/wp-json\/wp\/v2\/media?parent=18453"}],"wp:term":[{"taxonomy":"sector","embeddable":true,"href":"https:\/\/www.orteanext.com\/es\/wp-json\/wp\/v2\/sector?post=18453"},{"taxonomy":"tech","embeddable":true,"href":"https:\/\/www.orteanext.com\/es\/wp-json\/wp\/v2\/tech?post=18453"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}