{"id":12626,"date":"2024-07-11T14:48:55","date_gmt":"2024-07-11T12:48:55","guid":{"rendered":"https:\/\/www.orteanext.com\/case\/16-minimatic-for-a-large-european-port\/"},"modified":"2025-12-04T17:19:21","modified_gmt":"2025-12-04T16:19:21","slug":"16-minimatic-pour-un-grand-port-europeen","status":"publish","type":"case","link":"https:\/\/www.orteanext.com\/fr\/case-histories\/16-minimatic-pour-un-grand-port-europeen\/","title":{"rendered":"16 Minimatic pour un grand port europ\u00e9en"},"content":{"rendered":"<h3>LE CLIENT<\/h3>\n<p>Le client est l&rsquo;un des plus grands ports d&rsquo;Europe du Nord.<\/p>\n<p>&nbsp;<\/p>\n<h3>LE BESOIN<\/h3>\n<p>Ces grandes infrastructures ont une puissance install\u00e9e importante, mais souvent r\u00e9partie sur de tr\u00e8s grandes surfaces : la r\u00e9duction des courants en jeu est cruciale, tant pour l&rsquo;efficacit\u00e9 du syst\u00e8me que pour le respect de l&rsquo;environnement.<\/p>\n<p>&nbsp;<\/p>\n<h3>NOTRE SOLUTION<\/h3>\n<p>Pour r\u00e9soudre le probl\u00e8me du client, 16 unit\u00e9s de correction du facteur de puissance MINImatic HP20 80kvar 400V ont \u00e9t\u00e9 fournies, avec charpente IP55 : alimentation totale 1280kvar.<\/p>\n<p>Les appareils sont constitu\u00e9s de condensateurs robustes en polypropyl\u00e8ne m\u00e9tallis\u00e9 \u00e0 gradient \u00e9lev\u00e9 (tension nominale : 460V) et se caract\u00e9risent par une charpenterie particuli\u00e8rement robuste et hautement prot\u00e9g\u00e9e.<\/p>\n<p>Pour ces grandes infrastructures, une correction \u00e9tendue du facteur de puissance est toujours un choix optimal.<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/www.orteanext.com\/fr\/systemes-de-correction-du-facteur-de-puissance\/petits-compensateurs-de-phase-grands-resultats\/\"><strong>D\u00e9couvrir l\u2019article associ\u00e9<\/strong><\/a><\/p>\n","protected":false},"featured_media":12621,"template":"","sector":[24298],"tech":[24306],"class_list":["post-12626","case","type-case","status-publish","has-post-thumbnail","hentry","sector-services-fr","tech-systemes-de-correction-du-facteur-de-puissance"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Correction du facteur de puissance IP55 pour les zones c\u00f4ti\u00e8res<\/title>\n<meta name=\"description\" content=\"Correction du facteur de puissance distribu\u00e9 ICAR Minimatic HP20 1280kvar pour la qualit\u00e9 de l&#039;\u00e9nergie d&#039;un grand port du nord de l&#039;Europe.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.orteanext.com\/fr\/case-histories\/16-minimatic-pour-un-grand-port-europeen\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Correction du facteur de puissance IP55 pour les zones c\u00f4ti\u00e8res\" \/>\n<meta property=\"og:description\" content=\"Correction du facteur de puissance distribu\u00e9 ICAR Minimatic HP20 1280kvar pour la qualit\u00e9 de l&#039;\u00e9nergie d&#039;un grand port du nord de l&#039;Europe.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.orteanext.com\/fr\/case-histories\/16-minimatic-pour-un-grand-port-europeen\/\" \/>\n<meta property=\"og:site_name\" content=\"Ortea Next\" \/>\n<meta property=\"article:modified_time\" content=\"2025-12-04T16:19:21+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.orteanext.com\/wp-content\/uploads\/2024\/07\/PFC07.1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"580\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/case-histories\\\/16-minimatic-pour-un-grand-port-europeen\\\/\",\"url\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/case-histories\\\/16-minimatic-pour-un-grand-port-europeen\\\/\",\"name\":\"Correction du facteur de puissance IP55 pour les zones c\u00f4ti\u00e8res\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/case-histories\\\/16-minimatic-pour-un-grand-port-europeen\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/case-histories\\\/16-minimatic-pour-un-grand-port-europeen\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.orteanext.com\\\/wp-content\\\/uploads\\\/2024\\\/07\\\/PFC07.1.jpg\",\"datePublished\":\"2024-07-11T12:48:55+00:00\",\"dateModified\":\"2025-12-04T16:19:21+00:00\",\"description\":\"Correction du facteur de puissance distribu\u00e9 ICAR Minimatic HP20 1280kvar pour la qualit\u00e9 de l'\u00e9nergie d'un grand port du nord de l'Europe.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/case-histories\\\/16-minimatic-pour-un-grand-port-europeen\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/case-histories\\\/16-minimatic-pour-un-grand-port-europeen\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/case-histories\\\/16-minimatic-pour-un-grand-port-europeen\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.orteanext.com\\\/wp-content\\\/uploads\\\/2024\\\/07\\\/PFC07.1.jpg\",\"contentUrl\":\"https:\\\/\\\/www.orteanext.com\\\/wp-content\\\/uploads\\\/2024\\\/07\\\/PFC07.1.jpg\",\"width\":800,\"height\":580},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/case-histories\\\/16-minimatic-pour-un-grand-port-europeen\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Case Histories\",\"item\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/case-histories\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"16 Minimatic pour un grand port europ\u00e9en\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/#website\",\"url\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/\",\"name\":\"Ortea Next\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/#organization\",\"name\":\"Ortea SpA\",\"url\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.orteanext.com\\\/wp-content\\\/uploads\\\/2022\\\/05\\\/logo_ortea.svg\",\"contentUrl\":\"https:\\\/\\\/www.orteanext.com\\\/wp-content\\\/uploads\\\/2022\\\/05\\\/logo_ortea.svg\",\"width\":1,\"height\":1,\"caption\":\"Ortea SpA\"},\"image\":{\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/ortea\\\/\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCqwcSga4ZzG3ntf6hYRu_Nw?reload=9\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Correction du facteur de puissance IP55 pour les zones c\u00f4ti\u00e8res","description":"Correction du facteur de puissance distribu\u00e9 ICAR Minimatic HP20 1280kvar pour la qualit\u00e9 de l'\u00e9nergie d'un grand port du nord de l'Europe.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.orteanext.com\/fr\/case-histories\/16-minimatic-pour-un-grand-port-europeen\/","og_locale":"fr_FR","og_type":"article","og_title":"Correction du facteur de puissance IP55 pour les zones c\u00f4ti\u00e8res","og_description":"Correction du facteur de puissance distribu\u00e9 ICAR Minimatic HP20 1280kvar pour la qualit\u00e9 de l'\u00e9nergie d'un grand port du nord de l'Europe.","og_url":"https:\/\/www.orteanext.com\/fr\/case-histories\/16-minimatic-pour-un-grand-port-europeen\/","og_site_name":"Ortea Next","article_modified_time":"2025-12-04T16:19:21+00:00","og_image":[{"width":800,"height":580,"url":"https:\/\/www.orteanext.com\/wp-content\/uploads\/2024\/07\/PFC07.1.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.orteanext.com\/fr\/case-histories\/16-minimatic-pour-un-grand-port-europeen\/","url":"https:\/\/www.orteanext.com\/fr\/case-histories\/16-minimatic-pour-un-grand-port-europeen\/","name":"Correction du facteur de puissance IP55 pour les zones c\u00f4ti\u00e8res","isPartOf":{"@id":"https:\/\/www.orteanext.com\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.orteanext.com\/fr\/case-histories\/16-minimatic-pour-un-grand-port-europeen\/#primaryimage"},"image":{"@id":"https:\/\/www.orteanext.com\/fr\/case-histories\/16-minimatic-pour-un-grand-port-europeen\/#primaryimage"},"thumbnailUrl":"https:\/\/www.orteanext.com\/wp-content\/uploads\/2024\/07\/PFC07.1.jpg","datePublished":"2024-07-11T12:48:55+00:00","dateModified":"2025-12-04T16:19:21+00:00","description":"Correction du facteur de puissance distribu\u00e9 ICAR Minimatic HP20 1280kvar pour la qualit\u00e9 de l'\u00e9nergie d'un grand port du nord de l'Europe.","breadcrumb":{"@id":"https:\/\/www.orteanext.com\/fr\/case-histories\/16-minimatic-pour-un-grand-port-europeen\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.orteanext.com\/fr\/case-histories\/16-minimatic-pour-un-grand-port-europeen\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.orteanext.com\/fr\/case-histories\/16-minimatic-pour-un-grand-port-europeen\/#primaryimage","url":"https:\/\/www.orteanext.com\/wp-content\/uploads\/2024\/07\/PFC07.1.jpg","contentUrl":"https:\/\/www.orteanext.com\/wp-content\/uploads\/2024\/07\/PFC07.1.jpg","width":800,"height":580},{"@type":"BreadcrumbList","@id":"https:\/\/www.orteanext.com\/fr\/case-histories\/16-minimatic-pour-un-grand-port-europeen\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.orteanext.com\/fr\/"},{"@type":"ListItem","position":2,"name":"Case Histories","item":"https:\/\/www.orteanext.com\/fr\/case-histories\/"},{"@type":"ListItem","position":3,"name":"16 Minimatic pour un grand port europ\u00e9en"}]},{"@type":"WebSite","@id":"https:\/\/www.orteanext.com\/fr\/#website","url":"https:\/\/www.orteanext.com\/fr\/","name":"Ortea Next","description":"","publisher":{"@id":"https:\/\/www.orteanext.com\/fr\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.orteanext.com\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/www.orteanext.com\/fr\/#organization","name":"Ortea SpA","url":"https:\/\/www.orteanext.com\/fr\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.orteanext.com\/fr\/#\/schema\/logo\/image\/","url":"https:\/\/www.orteanext.com\/wp-content\/uploads\/2022\/05\/logo_ortea.svg","contentUrl":"https:\/\/www.orteanext.com\/wp-content\/uploads\/2022\/05\/logo_ortea.svg","width":1,"height":1,"caption":"Ortea SpA"},"image":{"@id":"https:\/\/www.orteanext.com\/fr\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/ortea\/","https:\/\/www.youtube.com\/channel\/UCqwcSga4ZzG3ntf6hYRu_Nw?reload=9"]}]}},"_links":{"self":[{"href":"https:\/\/www.orteanext.com\/fr\/wp-json\/wp\/v2\/case\/12626","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.orteanext.com\/fr\/wp-json\/wp\/v2\/case"}],"about":[{"href":"https:\/\/www.orteanext.com\/fr\/wp-json\/wp\/v2\/types\/case"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.orteanext.com\/fr\/wp-json\/wp\/v2\/media\/12621"}],"wp:attachment":[{"href":"https:\/\/www.orteanext.com\/fr\/wp-json\/wp\/v2\/media?parent=12626"}],"wp:term":[{"taxonomy":"sector","embeddable":true,"href":"https:\/\/www.orteanext.com\/fr\/wp-json\/wp\/v2\/sector?post=12626"},{"taxonomy":"tech","embeddable":true,"href":"https:\/\/www.orteanext.com\/fr\/wp-json\/wp\/v2\/tech?post=12626"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}