{"id":27608,"date":"2026-03-03T16:34:11","date_gmt":"2026-03-03T15:34:11","guid":{"rendered":"https:\/\/www.orteanext.com\/case-histories\/railway-ups-transformers-specification-driven-design-and-quarterly-scheduled-deliveries\/"},"modified":"2026-03-03T16:37:37","modified_gmt":"2026-03-03T15:37:37","slug":"ups-ferroviaires-conception-pilotee-par-la-specification-et-livraisons-trimestrielles-programmees","status":"publish","type":"case","link":"https:\/\/www.orteanext.com\/fr\/case-histories\/ups-ferroviaires-conception-pilotee-par-la-specification-et-livraisons-trimestrielles-programmees\/","title":{"rendered":"UPS FERROVIAIRES : CONCEPTION PILOTEE PAR LA SPECIFICATION ET LIVRAISONS TRIMESTRIELLES PROGRAMMEES"},"content":{"rendered":"<h2>LE CLIENT<\/h2>\n<p>Une entreprise italienne appartenant \u00e0 une grande multinationale fournissant des solutions d\u2019infrastructure int\u00e9gr\u00e9es pour l\u2019industrie ferroviaire mondiale, avec un besoin r\u00e9current de <a href=\"https:\/\/www.orteanext.com\/fr\/applications\/applications-technologiques\/charges-non-protegees\/\">transformateurs d\u00e9di\u00e9s aux syst\u00e8mes UPS<\/a>.<\/p>\n<p>&nbsp;<\/p>\n<h2>LE BESOIN<\/h2>\n<p>Dans le ferroviaire, la continuit\u00e9 est une exigence de syst\u00e8me : toute anomalie peut impacter fiabilit\u00e9 et s\u00e9curit\u00e9. Les transformateurs UPS doivent respecter des exigences strictes : redresseurs 12 pulses, harmoniques (pertes\/\u00e9chauffement), Vcc%\/Xcc% impos\u00e9s, courants d\u2019appel et \u00e0 vide, encombrement contraint et conformit\u00e9 aux normes ferroviaires d\u00e9di\u00e9es. Le projet demandait aussi une <strong>coh\u00e9rence lot apr\u00e8s lot<\/strong> et des <strong>livraisons cadenc\u00e9es<\/strong>.<\/p>\n<p>&nbsp;<\/p>\n<h2>NOTRE SOLUTION<\/h2>\n<p>Ortea a mis en \u0153uvre une approche <strong>pilot\u00e9e par la sp\u00e9cification<\/strong>, avec calcul <strong>multi-physique<\/strong> (magn\u00e9tique + thermique + m\u00e9canique) et industrialisation orient\u00e9e vers la r\u00e9p\u00e9tabilit\u00e9 : ma\u00eetrise des imp\u00e9dances inter-enroulements et des fuites, choix noyau\/mat\u00e9riaux pour limiter pertes et temp\u00e9rature en pr\u00e9sence d\u2019harmoniques, layout et terminaux conformes aux contraintes d\u2019installation, v\u00e9rifications et essais reproductibles. La fourniture a \u00e9t\u00e9 organis\u00e9e via un <strong>programme annuel avec livraisons trimestrielles<\/strong>, garantissant continuit\u00e9 et homog\u00e9n\u00e9it\u00e9 des performances.<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/www.orteanext.com\/fr\/transformateurs-et-reacteurs-bt\/ups-dans-les-infrastructures-ferroviaires-transformateurs-speciaux-ortea-entre-normes-qualite-et-fournitures-continues\/\"><strong>D\u00e9couvrir l\u2019article associ\u00e9<\/strong><\/a><\/p>\n","protected":false},"featured_media":27459,"template":"","sector":[24298],"tech":[24319],"class_list":["post-27608","case","type-case","status-publish","has-post-thumbnail","hentry","sector-services-fr","tech-transformateurs-racteurs"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Transformateurs UPS ferroviaires : conception sur mesure | Ortea<\/title>\n<meta name=\"description\" content=\"Transformateurs UPS ferroviaires pour des normes strictes et un encombrement r\u00e9duit. Fournitures continues avec livraisons programm\u00e9es.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.orteanext.com\/fr\/case-histories\/ups-ferroviaires-conception-pilotee-par-la-specification-et-livraisons-trimestrielles-programmees\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Transformateurs UPS ferroviaires : conception sur mesure | Ortea\" \/>\n<meta property=\"og:description\" content=\"Transformateurs UPS ferroviaires pour des normes strictes et un encombrement r\u00e9duit. Fournitures continues avec livraisons programm\u00e9es.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.orteanext.com\/fr\/case-histories\/ups-ferroviaires-conception-pilotee-par-la-specification-et-livraisons-trimestrielles-programmees\/\" \/>\n<meta property=\"og:site_name\" content=\"Ortea Next\" \/>\n<meta property=\"article:modified_time\" content=\"2026-03-03T15:37:37+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.orteanext.com\/wp-content\/uploads\/2026\/02\/26P07evd.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"580\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/case-histories\\\/ups-ferroviaires-conception-pilotee-par-la-specification-et-livraisons-trimestrielles-programmees\\\/\",\"url\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/case-histories\\\/ups-ferroviaires-conception-pilotee-par-la-specification-et-livraisons-trimestrielles-programmees\\\/\",\"name\":\"Transformateurs UPS ferroviaires : conception sur mesure | Ortea\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/case-histories\\\/ups-ferroviaires-conception-pilotee-par-la-specification-et-livraisons-trimestrielles-programmees\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/case-histories\\\/ups-ferroviaires-conception-pilotee-par-la-specification-et-livraisons-trimestrielles-programmees\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.orteanext.com\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/26P07evd.jpg\",\"datePublished\":\"2026-03-03T15:34:11+00:00\",\"dateModified\":\"2026-03-03T15:37:37+00:00\",\"description\":\"Transformateurs UPS ferroviaires pour des normes strictes et un encombrement r\u00e9duit. Fournitures continues avec livraisons programm\u00e9es.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/case-histories\\\/ups-ferroviaires-conception-pilotee-par-la-specification-et-livraisons-trimestrielles-programmees\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/case-histories\\\/ups-ferroviaires-conception-pilotee-par-la-specification-et-livraisons-trimestrielles-programmees\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/case-histories\\\/ups-ferroviaires-conception-pilotee-par-la-specification-et-livraisons-trimestrielles-programmees\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.orteanext.com\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/26P07evd.jpg\",\"contentUrl\":\"https:\\\/\\\/www.orteanext.com\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/26P07evd.jpg\",\"width\":800,\"height\":580},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/case-histories\\\/ups-ferroviaires-conception-pilotee-par-la-specification-et-livraisons-trimestrielles-programmees\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Case Histories\",\"item\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/case-histories\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"UPS FERROVIAIRES : CONCEPTION PILOTEE PAR LA SPECIFICATION ET LIVRAISONS TRIMESTRIELLES PROGRAMMEES\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/#website\",\"url\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/\",\"name\":\"Ortea Next\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/#organization\",\"name\":\"Ortea SpA\",\"url\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.orteanext.com\\\/wp-content\\\/uploads\\\/2022\\\/05\\\/logo_ortea.svg\",\"contentUrl\":\"https:\\\/\\\/www.orteanext.com\\\/wp-content\\\/uploads\\\/2022\\\/05\\\/logo_ortea.svg\",\"width\":1,\"height\":1,\"caption\":\"Ortea SpA\"},\"image\":{\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/ortea\\\/\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCqwcSga4ZzG3ntf6hYRu_Nw?reload=9\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Transformateurs UPS ferroviaires : conception sur mesure | Ortea","description":"Transformateurs UPS ferroviaires pour des normes strictes et un encombrement r\u00e9duit. Fournitures continues avec livraisons programm\u00e9es.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.orteanext.com\/fr\/case-histories\/ups-ferroviaires-conception-pilotee-par-la-specification-et-livraisons-trimestrielles-programmees\/","og_locale":"fr_FR","og_type":"article","og_title":"Transformateurs UPS ferroviaires : conception sur mesure | Ortea","og_description":"Transformateurs UPS ferroviaires pour des normes strictes et un encombrement r\u00e9duit. Fournitures continues avec livraisons programm\u00e9es.","og_url":"https:\/\/www.orteanext.com\/fr\/case-histories\/ups-ferroviaires-conception-pilotee-par-la-specification-et-livraisons-trimestrielles-programmees\/","og_site_name":"Ortea Next","article_modified_time":"2026-03-03T15:37:37+00:00","og_image":[{"width":800,"height":580,"url":"https:\/\/www.orteanext.com\/wp-content\/uploads\/2026\/02\/26P07evd.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.orteanext.com\/fr\/case-histories\/ups-ferroviaires-conception-pilotee-par-la-specification-et-livraisons-trimestrielles-programmees\/","url":"https:\/\/www.orteanext.com\/fr\/case-histories\/ups-ferroviaires-conception-pilotee-par-la-specification-et-livraisons-trimestrielles-programmees\/","name":"Transformateurs UPS ferroviaires : conception sur mesure | Ortea","isPartOf":{"@id":"https:\/\/www.orteanext.com\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.orteanext.com\/fr\/case-histories\/ups-ferroviaires-conception-pilotee-par-la-specification-et-livraisons-trimestrielles-programmees\/#primaryimage"},"image":{"@id":"https:\/\/www.orteanext.com\/fr\/case-histories\/ups-ferroviaires-conception-pilotee-par-la-specification-et-livraisons-trimestrielles-programmees\/#primaryimage"},"thumbnailUrl":"https:\/\/www.orteanext.com\/wp-content\/uploads\/2026\/02\/26P07evd.jpg","datePublished":"2026-03-03T15:34:11+00:00","dateModified":"2026-03-03T15:37:37+00:00","description":"Transformateurs UPS ferroviaires pour des normes strictes et un encombrement r\u00e9duit. Fournitures continues avec livraisons programm\u00e9es.","breadcrumb":{"@id":"https:\/\/www.orteanext.com\/fr\/case-histories\/ups-ferroviaires-conception-pilotee-par-la-specification-et-livraisons-trimestrielles-programmees\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.orteanext.com\/fr\/case-histories\/ups-ferroviaires-conception-pilotee-par-la-specification-et-livraisons-trimestrielles-programmees\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.orteanext.com\/fr\/case-histories\/ups-ferroviaires-conception-pilotee-par-la-specification-et-livraisons-trimestrielles-programmees\/#primaryimage","url":"https:\/\/www.orteanext.com\/wp-content\/uploads\/2026\/02\/26P07evd.jpg","contentUrl":"https:\/\/www.orteanext.com\/wp-content\/uploads\/2026\/02\/26P07evd.jpg","width":800,"height":580},{"@type":"BreadcrumbList","@id":"https:\/\/www.orteanext.com\/fr\/case-histories\/ups-ferroviaires-conception-pilotee-par-la-specification-et-livraisons-trimestrielles-programmees\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.orteanext.com\/fr\/"},{"@type":"ListItem","position":2,"name":"Case Histories","item":"https:\/\/www.orteanext.com\/fr\/case-histories\/"},{"@type":"ListItem","position":3,"name":"UPS FERROVIAIRES : CONCEPTION PILOTEE PAR LA SPECIFICATION ET LIVRAISONS TRIMESTRIELLES PROGRAMMEES"}]},{"@type":"WebSite","@id":"https:\/\/www.orteanext.com\/fr\/#website","url":"https:\/\/www.orteanext.com\/fr\/","name":"Ortea Next","description":"","publisher":{"@id":"https:\/\/www.orteanext.com\/fr\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.orteanext.com\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/www.orteanext.com\/fr\/#organization","name":"Ortea SpA","url":"https:\/\/www.orteanext.com\/fr\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.orteanext.com\/fr\/#\/schema\/logo\/image\/","url":"https:\/\/www.orteanext.com\/wp-content\/uploads\/2022\/05\/logo_ortea.svg","contentUrl":"https:\/\/www.orteanext.com\/wp-content\/uploads\/2022\/05\/logo_ortea.svg","width":1,"height":1,"caption":"Ortea SpA"},"image":{"@id":"https:\/\/www.orteanext.com\/fr\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/ortea\/","https:\/\/www.youtube.com\/channel\/UCqwcSga4ZzG3ntf6hYRu_Nw?reload=9"]}]}},"_links":{"self":[{"href":"https:\/\/www.orteanext.com\/fr\/wp-json\/wp\/v2\/case\/27608","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.orteanext.com\/fr\/wp-json\/wp\/v2\/case"}],"about":[{"href":"https:\/\/www.orteanext.com\/fr\/wp-json\/wp\/v2\/types\/case"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.orteanext.com\/fr\/wp-json\/wp\/v2\/media\/27459"}],"wp:attachment":[{"href":"https:\/\/www.orteanext.com\/fr\/wp-json\/wp\/v2\/media?parent=27608"}],"wp:term":[{"taxonomy":"sector","embeddable":true,"href":"https:\/\/www.orteanext.com\/fr\/wp-json\/wp\/v2\/sector?post=27608"},{"taxonomy":"tech","embeddable":true,"href":"https:\/\/www.orteanext.com\/fr\/wp-json\/wp\/v2\/tech?post=27608"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}