{"id":26710,"date":"2025-12-16T09:17:44","date_gmt":"2025-12-16T08:17:44","guid":{"rendered":"https:\/\/www.orteanext.com\/nouvelles\/medium-voltage-current-limiting-reactor-orteas-custom-solution-for-grid-connected-generation\/"},"modified":"2026-09-17T09:33:32","modified_gmt":"2026-09-17T07:33:32","slug":"reactance-limitatrice-de-courant-moyenne-tension-la-solution-sur-mesure-dortea-pour-la-production-connectee-au-reseau","status":"publish","type":"post","link":"https:\/\/www.orteanext.com\/fr\/transformateurs-et-reacteurs-bt\/reactance-limitatrice-de-courant-moyenne-tension-la-solution-sur-mesure-dortea-pour-la-production-connectee-au-reseau\/","title":{"rendered":"R\u00c9ACTANCE LIMITATRICE DE COURANT MOYENNE TENSION : LA SOLUTION SUR MESURE D\u2019ORTEA POUR LA PRODUCTION CONNECT\u00c9E AU R\u00c9SEAU"},"content":{"rendered":"<p>orsqu\u2019une installation de production est raccord\u00e9e au r\u00e9seau du distributeur (DSO), le courant de court-circuit pouvant circuler vers le r\u00e9seau public en cas de d\u00e9faut devient un param\u00e8tre critique pour la s\u00e9curit\u00e9 et la power quality.<\/p>\n<p>Si la contribution des groupes de production du client est trop \u00e9lev\u00e9e, les protections du DSO peuvent ne plus \u00eatre adapt\u00e9es et le raccordement risque de ne pas \u00eatre accept\u00e9 ou d\u2019exiger des renforcements co\u00fbteux c\u00f4t\u00e9 r\u00e9seau.<\/p>\n<p>Pour r\u00e9soudre ce probl\u00e8me, Ortea a con\u00e7u et r\u00e9alis\u00e9 une <strong>r\u00e9actance limitatrice de courant moyenne tension<\/strong> enti\u00e8rement personnalis\u00e9e, d\u00e9velopp\u00e9e \u00e0 partir des sp\u00e9cifications techniques du client, des limites impos\u00e9es par le DSO et des contraintes logistiques d\u2019installation.<\/p>\n<p>&nbsp;<\/p>\n<h2>LE PROBL\u00c8ME DU CLIENT : LIMITER LA CONTRIBUTION DE COURT-CIRCUIT VERS LE R\u00c9SEAU DU DSO<\/h2>\n<p>Dans ce cas, le client dispose de plusieurs groupes de production en moyenne tension connect\u00e9s au r\u00e9seau public. En cas de panne sur le r\u00e9seau du DSO, les g\u00e9n\u00e9rateurs contribuent au courant de court-circuit dans une mesure telle qu&rsquo;ils <strong>d\u00e9passent les limites impos\u00e9es par le gestionnaire de r\u00e9seau<\/strong>.<\/p>\n<p>Les objectifs principaux \u00e9taient les suivants :<\/p>\n<ul>\n<li><strong>R\u00e9duire le courant de court-circuit<\/strong> renvoy\u00e9 vers le r\u00e9seau public, afin de le ramener dans les limites exig\u00e9es par le DSO.<\/li>\n<li><strong>Maintenir des niveaux de tension et des performances ad\u00e9quats en service normal<\/strong>, en limitant la chute de tension et les pertes en r\u00e9gime permanent.<\/li>\n<li><strong>Respecter des contraintes dimensionnelles strictes<\/strong> pour l\u2019installation, li\u00e9es aux espaces disponibles et aux op\u00e9rations de manutention sur site (acc\u00e8s, ouvertures, moyens de levage).<\/li>\n<\/ul>\n<p>D\u2019un point de vue \u00e9lectrique, la solution choisie a consist\u00e9 \u00e0 ins\u00e9rer <strong>un r\u00e9acteur de ligne en s\u00e9rie<\/strong> entre les groupes de production du client et le r\u00e9seau du DSO, dimensionn\u00e9 avec une inductance suffisante pour r\u00e9duire de fa\u00e7on significative le courant de d\u00e9faut, sans p\u00e9naliser le fonctionnement normal de l\u2019installation ni la qualit\u00e9 de l\u2019\u00e9nergie.<\/p>\n<p>&nbsp;<\/p>\n<h2>QU\u2019EST-CE QU\u2019UNE R\u00c9ACTANCE LIMITATRICE DE COURANT MOYENNE TENSION ?<\/h2>\n<p>Une <strong>r\u00e9actance limitatrice de courant en moyenne tension<\/strong> (ou <em>current limiting reactor<\/em>) est une inductance de puissance install\u00e9e <strong>en s\u00e9rie<\/strong> sur la ligne, con\u00e7ue pour ma\u00eetriser le niveau de courant de court-circuit vu par le r\u00e9seau et par les \u00e9quipements raccord\u00e9s.<\/p>\n<p>Elle est typiquement install\u00e9e :<\/p>\n<ul>\n<li>entre des g\u00e9n\u00e9rateurs et le r\u00e9seau public ;<\/li>\n<li>entre diff\u00e9rents tron\u00e7ons d\u2019un syst\u00e8me en boucle ;<\/li>\n<li>ou en amont de charges sensibles.<\/li>\n<\/ul>\n<p>Ses fonctions principales sont :<\/p>\n<ul>\n<li><strong>Limiter le courant de court-circuit<\/strong> vu par les protections et les \u00e9quipements en aval.<\/li>\n<li><strong>Permettre le raccordement au r\u00e9seau<\/strong> m\u00eame en pr\u00e9sence de g\u00e9n\u00e9rateurs qui augmentent le niveau de court-circuit au-del\u00e0 des limites autoris\u00e9es.<\/li>\n<li><strong>Prot\u00e9ger disjoncteurs, jeux de barres et c\u00e2bles<\/strong>, en \u00e9vitant leur surdimensionnement.<\/li>\n<\/ul>\n<p>Une conception correcte doit trouver un \u00e9quilibre entre :<\/p>\n<ul>\n<li>la valeur d\u2019inductance (et donc le niveau de limitation du courant de court-circuit) ;<\/li>\n<li>la chute de tension admissible en r\u00e9gime permanent ;<\/li>\n<li>les pertes, le comportement thermique et la conformit\u00e9 aux normes applicables.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h2>LA SOLUTION ORTEA : UNE R\u00c9ACTANCE SUR MESURE POUR LA MOYENNE TENSION<\/h2>\n<p>\u00c0 partir des donn\u00e9es de r\u00e9seau, des caract\u00e9ristiques des g\u00e9n\u00e9rateurs et des limites impos\u00e9es par le DSO, les ing\u00e9nieurs d\u2019Ortea ont d\u00e9velopp\u00e9 une <strong>r\u00e9actance limitatrice de courant moyenne tension<\/strong> pr\u00e9sentant les caract\u00e9ristiques principales suivantes :<\/p>\n<ul>\n<li>Puissance nominale du r\u00e9acteur : 181 Kva<\/li>\n<li>Tension nominale : 10 kV<\/li>\n<li>Courant nominal : 80 A<\/li>\n<li>Inductance : 30 mH<\/li>\n<li>Imp\u00e9dance de court-circuit : 13 % @ 50 Hz<\/li>\n<li>Chute de tension \u00e0 la charge nominale : ~750 V<\/li>\n<li>Puissance de charge associ\u00e9e : 1400 kVA<\/li>\n<\/ul>\n<p>La construction est de type <strong>air-core<\/strong> (noyau \u00e0 air) avec <strong>enroulements en aluminium<\/strong>, un choix qui garantit la stabilit\u00e9 des caract\u00e9ristiques dans le temps, une grande robustesse m\u00e9canique et une bonne tenue aux efforts \u00e9lectrodynamiques en cas de d\u00e9faut.<\/p>\n<p>Du point de vue de l\u2019isolement :<\/p>\n<ul>\n<li>Tension maximale de service : 12 kV<\/li>\n<li>Tension tenue \u00e0 fr\u00e9quence industrielle (1 min) : 30 kV<\/li>\n<li>Tension tenue aux chocs de foudre (BIL) : 75 kV<\/li>\n<li>Classe d\u2019isolation et thermique : H, avec une sur temp\u00e9rature admissible de 125 \u00b0C<\/li>\n<\/ul>\n<p>La r\u00e9actance est impr\u00e9gn\u00e9e en <strong>VPI (<em>dry<\/em>)<\/strong>, adapt\u00e9e pour une <strong>installation indoor en ex\u00e9cution IP00<\/strong>, avec classe environnementale E1-C1-F0 et une altitude maximale de service de 1000 m.<\/p>\n<p>&nbsp;<\/p>\n<h2>CONCEPTION SUR MESURE : CONTRAINTES \u00c9LECTRIQUES, THERMIQUES ET M\u00c9CANIQUES<\/h2>\n<p>Au-del\u00e0 du dimensionnement \u00e9lectromagn\u00e9tique, le projet a d\u00fb satisfaire des contraintes strictes en termes de :<\/p>\n<ul>\n<li>dimensions globales, pour permettre l\u2019introduction et la mise en place de la r\u00e9actance dans des locaux existants sans travaux de g\u00e9nie civil lourds ;<\/li>\n<li>poids et points de levage, afin de faciliter la manutention sur chantier ;<\/li>\n<li>distances d\u2019isolement et layout des isolateurs, en conformit\u00e9 avec la norme EN 60076-6 pour les r\u00e9acteurs de puissance.<\/li>\n<\/ul>\n<p>La r\u00e9actance r\u00e9alis\u00e9e par Ortea pr\u00e9sente des dimensions de 1250 x 1250 x 1960 mm (L x P x H) et un poids d\u2019environ 800 kg, valeurs optimis\u00e9es pour respecter les contraintes d\u2019acc\u00e8s au site et les exigences d\u2019installation du client.<\/p>\n<p>Le projet a n\u00e9cessit\u00e9 une collaboration \u00e9troite entre :<\/p>\n<ul>\n<li>le bureau d\u2019\u00e9tudes du client, pour la d\u00e9finition des donn\u00e9es de r\u00e9seau, des g\u00e9n\u00e9rateurs et des logiques de protection ;<\/li>\n<li>les sp\u00e9cialistes Ortea, qui ont r\u00e9alis\u00e9 le dimensionnement \u00e9lectrique et thermique de la r\u00e9actance, la v\u00e9rification des pertes (environ 8,1 kW totales AC+DC \u00e0 115 \u00b0C) et la conception m\u00e9canique de la structure.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h2>AVANTAGES POUR LE CLIENT ET POUR LE GESTIONNAIRE DE R\u00c9SEAU<\/h2>\n<p>Gr\u00e2ce \u00e0 la r\u00e9actance limitatrice de courant moyenne tension con\u00e7ue par Ortea Next, le client b\u00e9n\u00e9ficie :<\/p>\n<ul>\n<li><strong>de la conformit\u00e9 aux limites de court-circuit du DSO<\/strong>, sans intervention sur l\u2019infrastructure du r\u00e9seau public ;<\/li>\n<li><strong>d\u2019un meilleur coordination des protections<\/strong>, avec des courants de d\u00e9faut dans la plage de r\u00e9glage pr\u00e9vue ;<\/li>\n<li><strong>de la protection des \u00e9quipements<\/strong> (disjoncteurs, tableaux, jeux de barres) contre des sollicitations excessives ;<\/li>\n<li><strong>d\u2019une solution parfaitement int\u00e9gr\u00e9e au layout de l\u2019installation<\/strong>, gr\u00e2ce au respect des contraintes dimensionnelles et logistiques ;<\/li>\n<li><strong>d\u2019une fiabilit\u00e9 dans le temps<\/strong>, renforc\u00e9e par le choix des mat\u00e9riaux, l\u2019isolation en classe H et le proc\u00e9d\u00e9 d\u2019impr\u00e9gnation VPI.<\/li>\n<\/ul>\n<p>Pour le gestionnaire de r\u00e9seau, la pr\u00e9sence de la r\u00e9actance permet :<\/p>\n<ul>\n<li>de limiter l\u2019impact de la production du client sur le niveau de court-circuit du r\u00e9seau ;<\/li>\n<li>de garantir le bon fonctionnement et la s\u00e9lectivit\u00e9 des protections ;<\/li>\n<li>de faciliter l\u2019int\u00e9gration de nouvelles productions distribu\u00e9es sans compromettre la s\u00e9curit\u00e9 de l\u2019infrastructure existante.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h2>POURQUOI CHOISIR ORTEA POUR DES SOLUTIONS SUR MESURE ?<\/h2>\n<p>Ce projet illustre la capacit\u00e9 d\u2019Ortea \u00e0 :<\/p>\n<ul>\n<li><strong>partir de sp\u00e9cifications syst\u00e8me complexes<\/strong> (donn\u00e9es de r\u00e9seau, g\u00e9n\u00e9rateurs, protections, limites du DSO) ;<\/li>\n<li><strong>les transformer en une solution \u00e9lectrotechnique concr\u00e8te<\/strong>, avec un r\u00e9acteur de ligne dimensionn\u00e9 exactement pour le niveau de limitation requis ;<\/li>\n<li><strong>concevoir l\u2019appareillage sur mesure<\/strong> \u00e9galement du point de vue m\u00e9canique et logistique, en respectant les encombrements et les contraintes d\u2019installation.<\/li>\n<\/ul>\n<p>Qu\u2019il s\u2019agisse de <strong>r\u00e9actances limitatrices de courant moyenne tension<\/strong>, de r\u00e9acteurs de ligne, de filtres ou d\u2019autres \u00e9quipements sp\u00e9ciaux, Ortea met \u00e0 disposition un know-how solide en :<\/p>\n<ul>\n<li>conception \u00e9lectromagn\u00e9tique et thermique ;<\/li>\n<li>v\u00e9rification des performances en r\u00e9gime normal et en r\u00e9gime de d\u00e9faut ;<\/li>\n<li>conformit\u00e9 aux normes de r\u00e9f\u00e9rence ;<\/li>\n<li>personnalisation m\u00e9canique et int\u00e9gration dans l\u2019installation.<\/li>\n<\/ul>\n<p>L\u2019ensemble s\u2019inscrit dans un portefeuille complet de solutions pour la power quality et l\u2019efficacit\u00e9 \u00e9nerg\u00e9tique, enti\u00e8rement con\u00e7ues et fabriqu\u00e9es en Italie et support\u00e9es par un r\u00e9seau international de sp\u00e9cialistes.<\/p>\n<p>&nbsp;<\/p>\n<h2>FAQ SUR LA LIMITATION DU COURANT DE COURT-CIRCUIT EN MOYENNE TENSION<\/h2>\n<h3>POURQUOI INSTALLER UNE REACTANCE LIMITATRICE EN PRESENCE DE GENERATEURS CONNECTES AU RESEAU ?<\/h3>\n<p>Lorsqu\u2019une installation de production est raccord\u00e9e au r\u00e9seau du DSO, les g\u00e9n\u00e9rateurs contribuent au courant de court-circuit en cas de d\u00e9faut. Si cette contribution d\u00e9passe les limites admises par le gestionnaire, les protections et les \u00e9quipements de r\u00e9seau peuvent ne plus \u00eatre adapt\u00e9s. Une r\u00e9actance limitatrice moyenne tension r\u00e9duit le courant de d\u00e9faut \u00e0 un niveau compatible avec les sp\u00e9cifications du DSO et permet le raccordement de l\u2019installation en toute s\u00e9curit\u00e9.<\/p>\n<h3>COMMENT DIMENSIONNER UNE REACTANCE LIMITATRICE DE COURANT MOYENNE TENSION ?<\/h3>\n<p>Le dimensionnement part des donn\u00e9es de r\u00e9seau, des caract\u00e9ristiques des g\u00e9n\u00e9rateurs et des limites de court-circuit impos\u00e9es par le DSO. On d\u00e9finit la valeur d\u2019inductance n\u00e9cessaire pour r\u00e9duire le courant de d\u00e9faut, tout en v\u00e9rifiant la chute de tension et les pertes en service normal. Ortea r\u00e9alise \u00e9galement les v\u00e9rifications thermiques et m\u00e9caniques afin de garantir la fiabilit\u00e9, la dur\u00e9e de vie et la conformit\u00e9 aux normes applicables.<\/p>\n<h3>QUELS AVANTAGES OFFRE UNE REACTANCE LIMITATRICE PAR RAPPORT AU SIMPLE SURDIMENSIONNEMENT DES EQUIPEMENTS ?<\/h3>\n<p>Sans r\u00e9actance, l\u2019alternative consiste souvent \u00e0 surdimensionner disjoncteurs, jeux de barres et tableaux, avec des co\u00fbts tr\u00e8s \u00e9lev\u00e9s et d\u2019\u00e9ventuelles modifications structurelles de l\u2019installation. La r\u00e9actance limitatrice permet de maintenir le courant de court-circuit dans des valeurs supportables par les \u00e9quipements existants ou par des appareils standard, simplifiant la coordination des protections et r\u00e9duisant l\u2019investissement global.<\/p>\n<h3>COMMENT ORTEA PERSONNALISE-T-ELLE LES REACTANCES MOYENNE TENSION SELON LES BESOINS DU CLIENT ?<\/h3>\n<p>Ortea con\u00e7oit des r\u00e9actances moyenne tension \u00e0 partir des sp\u00e9cifications \u00e9lectriques (tension, courant, inductance, imp\u00e9dance de court-circuit) et des contraintes d\u2019installation (dimensions, poids, mode de montage, layout des connexions). Les mat\u00e9riaux, la classe d\u2019isolation, le syst\u00e8me de refroidissement et la configuration m\u00e9canique sont \u00e9galement personnalis\u00e9s, afin de proposer une solution sur mesure parfaitement int\u00e9gr\u00e9e dans l\u2019installation du client et coh\u00e9rente avec ses objectifs d\u2019efficacit\u00e9 \u00e9nerg\u00e9tique et de fiabilit\u00e9.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>orsqu\u2019une installation de production est raccord\u00e9e au r\u00e9seau du distributeur (DSO), le courant de court-circuit pouvant circuler vers le r\u00e9seau public en cas de d\u00e9faut devient un param\u00e8tre critique pour la s\u00e9curit\u00e9 et la power quality. Si la contribution des groupes de production du client est trop \u00e9lev\u00e9e, les protections du DSO peuvent ne plus [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":26711,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":""},"categories":[20100],"tags":[],"class_list":["post-26710","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-transformateurs-et-reacteurs-bt"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>R\u00e9actance limiteuse de courant MT : \u00e0 quoi sert-elle ?<\/title>\n<meta name=\"description\" content=\"Qu&#039;est-ce que la r\u00e9actance limiteuse de courant en moyenne tension, quand est-elle n\u00e9cessaire et comment Ortea la con\u00e7oit-elle sur mesure pour la production raccord\u00e9e au r\u00e9seau ?\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.orteanext.com\/fr\/transformateurs-et-reacteurs-bt\/reactance-limitatrice-de-courant-moyenne-tension-la-solution-sur-mesure-dortea-pour-la-production-connectee-au-reseau\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"R\u00e9actance limiteuse de courant MT : \u00e0 quoi sert-elle ?\" \/>\n<meta property=\"og:description\" content=\"Qu&#039;est-ce que la r\u00e9actance limiteuse de courant en moyenne tension, quand est-elle n\u00e9cessaire et comment Ortea la con\u00e7oit-elle sur mesure pour la production raccord\u00e9e au r\u00e9seau ?\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.orteanext.com\/fr\/transformateurs-et-reacteurs-bt\/reactance-limitatrice-de-courant-moyenne-tension-la-solution-sur-mesure-dortea-pour-la-production-connectee-au-reseau\/\" \/>\n<meta property=\"og:site_name\" content=\"Ortea Next\" \/>\n<meta property=\"article:published_time\" content=\"2025-12-16T08:17:44+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-17T07:33:32+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.orteanext.com\/wp-content\/uploads\/2025\/12\/P50evd.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"580\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Pietro Cereda\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"Pietro Cereda\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"8 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/transformateurs-et-reacteurs-bt\\\/reactance-limitatrice-de-courant-moyenne-tension-la-solution-sur-mesure-dortea-pour-la-production-connectee-au-reseau\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/transformateurs-et-reacteurs-bt\\\/reactance-limitatrice-de-courant-moyenne-tension-la-solution-sur-mesure-dortea-pour-la-production-connectee-au-reseau\\\/\"},\"author\":{\"name\":\"Pietro Cereda\",\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/#\\\/schema\\\/person\\\/fad56b88aae6c39db6d72d033199b714\"},\"headline\":\"R\u00c9ACTANCE LIMITATRICE DE COURANT MOYENNE TENSION : LA SOLUTION SUR MESURE D\u2019ORTEA POUR LA PRODUCTION CONNECT\u00c9E AU R\u00c9SEAU\",\"datePublished\":\"2025-12-16T08:17:44+00:00\",\"dateModified\":\"2026-09-17T07:33:32+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/transformateurs-et-reacteurs-bt\\\/reactance-limitatrice-de-courant-moyenne-tension-la-solution-sur-mesure-dortea-pour-la-production-connectee-au-reseau\\\/\"},\"wordCount\":1730,\"publisher\":{\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/transformateurs-et-reacteurs-bt\\\/reactance-limitatrice-de-courant-moyenne-tension-la-solution-sur-mesure-dortea-pour-la-production-connectee-au-reseau\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.orteanext.com\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/P50evd.jpg\",\"articleSection\":[\"Transformateurs et r\u00e9acteurs\"],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/transformateurs-et-reacteurs-bt\\\/reactance-limitatrice-de-courant-moyenne-tension-la-solution-sur-mesure-dortea-pour-la-production-connectee-au-reseau\\\/\",\"url\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/transformateurs-et-reacteurs-bt\\\/reactance-limitatrice-de-courant-moyenne-tension-la-solution-sur-mesure-dortea-pour-la-production-connectee-au-reseau\\\/\",\"name\":\"R\u00e9actance limiteuse de courant MT : \u00e0 quoi sert-elle ?\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/transformateurs-et-reacteurs-bt\\\/reactance-limitatrice-de-courant-moyenne-tension-la-solution-sur-mesure-dortea-pour-la-production-connectee-au-reseau\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/transformateurs-et-reacteurs-bt\\\/reactance-limitatrice-de-courant-moyenne-tension-la-solution-sur-mesure-dortea-pour-la-production-connectee-au-reseau\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.orteanext.com\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/P50evd.jpg\",\"datePublished\":\"2025-12-16T08:17:44+00:00\",\"dateModified\":\"2026-09-17T07:33:32+00:00\",\"description\":\"Qu'est-ce que la r\u00e9actance limiteuse de courant en moyenne tension, quand est-elle n\u00e9cessaire et comment Ortea la con\u00e7oit-elle sur mesure pour la production raccord\u00e9e au r\u00e9seau ?\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/transformateurs-et-reacteurs-bt\\\/reactance-limitatrice-de-courant-moyenne-tension-la-solution-sur-mesure-dortea-pour-la-production-connectee-au-reseau\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/transformateurs-et-reacteurs-bt\\\/reactance-limitatrice-de-courant-moyenne-tension-la-solution-sur-mesure-dortea-pour-la-production-connectee-au-reseau\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/transformateurs-et-reacteurs-bt\\\/reactance-limitatrice-de-courant-moyenne-tension-la-solution-sur-mesure-dortea-pour-la-production-connectee-au-reseau\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.orteanext.com\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/P50evd.jpg\",\"contentUrl\":\"https:\\\/\\\/www.orteanext.com\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/P50evd.jpg\",\"width\":800,\"height\":580},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/transformateurs-et-reacteurs-bt\\\/reactance-limitatrice-de-courant-moyenne-tension-la-solution-sur-mesure-dortea-pour-la-production-connectee-au-reseau\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Transformateurs et r\u00e9acteurs\",\"item\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/cat\\\/transformateurs-et-reacteurs-bt\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"R\u00c9ACTANCE LIMITATRICE DE COURANT MOYENNE TENSION : LA SOLUTION SUR MESURE D\u2019ORTEA POUR LA PRODUCTION CONNECT\u00c9E AU R\u00c9SEAU\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/#website\",\"url\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/\",\"name\":\"Ortea Next\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/#organization\",\"name\":\"Ortea SpA\",\"url\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.orteanext.com\\\/wp-content\\\/uploads\\\/2022\\\/05\\\/logo_ortea.svg\",\"contentUrl\":\"https:\\\/\\\/www.orteanext.com\\\/wp-content\\\/uploads\\\/2022\\\/05\\\/logo_ortea.svg\",\"width\":1,\"height\":1,\"caption\":\"Ortea SpA\"},\"image\":{\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/ortea\\\/\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCqwcSga4ZzG3ntf6hYRu_Nw?reload=9\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/#\\\/schema\\\/person\\\/fad56b88aae6c39db6d72d033199b714\",\"name\":\"Pietro Cereda\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/be648c51974652a1c39aa0ed2ef0f3d777b546eda44f9d5eb9c82ed8226bcf84?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/be648c51974652a1c39aa0ed2ef0f3d777b546eda44f9d5eb9c82ed8226bcf84?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/be648c51974652a1c39aa0ed2ef0f3d777b546eda44f9d5eb9c82ed8226bcf84?s=96&d=mm&r=g\",\"caption\":\"Pietro Cereda\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"R\u00e9actance limiteuse de courant MT : \u00e0 quoi sert-elle ?","description":"Qu'est-ce que la r\u00e9actance limiteuse de courant en moyenne tension, quand est-elle n\u00e9cessaire et comment Ortea la con\u00e7oit-elle sur mesure pour la production raccord\u00e9e au r\u00e9seau ?","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.orteanext.com\/fr\/transformateurs-et-reacteurs-bt\/reactance-limitatrice-de-courant-moyenne-tension-la-solution-sur-mesure-dortea-pour-la-production-connectee-au-reseau\/","og_locale":"fr_FR","og_type":"article","og_title":"R\u00e9actance limiteuse de courant MT : \u00e0 quoi sert-elle ?","og_description":"Qu'est-ce que la r\u00e9actance limiteuse de courant en moyenne tension, quand est-elle n\u00e9cessaire et comment Ortea la con\u00e7oit-elle sur mesure pour la production raccord\u00e9e au r\u00e9seau ?","og_url":"https:\/\/www.orteanext.com\/fr\/transformateurs-et-reacteurs-bt\/reactance-limitatrice-de-courant-moyenne-tension-la-solution-sur-mesure-dortea-pour-la-production-connectee-au-reseau\/","og_site_name":"Ortea Next","article_published_time":"2025-12-16T08:17:44+00:00","article_modified_time":"2026-09-17T07:33:32+00:00","og_image":[{"width":800,"height":580,"url":"https:\/\/www.orteanext.com\/wp-content\/uploads\/2025\/12\/P50evd.jpg","type":"image\/jpeg"}],"author":"Pietro Cereda","twitter_card":"summary_large_image","twitter_misc":{"\u00c9crit par":"Pietro Cereda","Dur\u00e9e de lecture estim\u00e9e":"8 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.orteanext.com\/fr\/transformateurs-et-reacteurs-bt\/reactance-limitatrice-de-courant-moyenne-tension-la-solution-sur-mesure-dortea-pour-la-production-connectee-au-reseau\/#article","isPartOf":{"@id":"https:\/\/www.orteanext.com\/fr\/transformateurs-et-reacteurs-bt\/reactance-limitatrice-de-courant-moyenne-tension-la-solution-sur-mesure-dortea-pour-la-production-connectee-au-reseau\/"},"author":{"name":"Pietro Cereda","@id":"https:\/\/www.orteanext.com\/fr\/#\/schema\/person\/fad56b88aae6c39db6d72d033199b714"},"headline":"R\u00c9ACTANCE LIMITATRICE DE COURANT MOYENNE TENSION : LA SOLUTION SUR MESURE D\u2019ORTEA POUR LA PRODUCTION CONNECT\u00c9E AU R\u00c9SEAU","datePublished":"2025-12-16T08:17:44+00:00","dateModified":"2026-09-17T07:33:32+00:00","mainEntityOfPage":{"@id":"https:\/\/www.orteanext.com\/fr\/transformateurs-et-reacteurs-bt\/reactance-limitatrice-de-courant-moyenne-tension-la-solution-sur-mesure-dortea-pour-la-production-connectee-au-reseau\/"},"wordCount":1730,"publisher":{"@id":"https:\/\/www.orteanext.com\/fr\/#organization"},"image":{"@id":"https:\/\/www.orteanext.com\/fr\/transformateurs-et-reacteurs-bt\/reactance-limitatrice-de-courant-moyenne-tension-la-solution-sur-mesure-dortea-pour-la-production-connectee-au-reseau\/#primaryimage"},"thumbnailUrl":"https:\/\/www.orteanext.com\/wp-content\/uploads\/2025\/12\/P50evd.jpg","articleSection":["Transformateurs et r\u00e9acteurs"],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/www.orteanext.com\/fr\/transformateurs-et-reacteurs-bt\/reactance-limitatrice-de-courant-moyenne-tension-la-solution-sur-mesure-dortea-pour-la-production-connectee-au-reseau\/","url":"https:\/\/www.orteanext.com\/fr\/transformateurs-et-reacteurs-bt\/reactance-limitatrice-de-courant-moyenne-tension-la-solution-sur-mesure-dortea-pour-la-production-connectee-au-reseau\/","name":"R\u00e9actance limiteuse de courant MT : \u00e0 quoi sert-elle ?","isPartOf":{"@id":"https:\/\/www.orteanext.com\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.orteanext.com\/fr\/transformateurs-et-reacteurs-bt\/reactance-limitatrice-de-courant-moyenne-tension-la-solution-sur-mesure-dortea-pour-la-production-connectee-au-reseau\/#primaryimage"},"image":{"@id":"https:\/\/www.orteanext.com\/fr\/transformateurs-et-reacteurs-bt\/reactance-limitatrice-de-courant-moyenne-tension-la-solution-sur-mesure-dortea-pour-la-production-connectee-au-reseau\/#primaryimage"},"thumbnailUrl":"https:\/\/www.orteanext.com\/wp-content\/uploads\/2025\/12\/P50evd.jpg","datePublished":"2025-12-16T08:17:44+00:00","dateModified":"2026-09-17T07:33:32+00:00","description":"Qu'est-ce que la r\u00e9actance limiteuse de courant en moyenne tension, quand est-elle n\u00e9cessaire et comment Ortea la con\u00e7oit-elle sur mesure pour la production raccord\u00e9e au r\u00e9seau ?","breadcrumb":{"@id":"https:\/\/www.orteanext.com\/fr\/transformateurs-et-reacteurs-bt\/reactance-limitatrice-de-courant-moyenne-tension-la-solution-sur-mesure-dortea-pour-la-production-connectee-au-reseau\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.orteanext.com\/fr\/transformateurs-et-reacteurs-bt\/reactance-limitatrice-de-courant-moyenne-tension-la-solution-sur-mesure-dortea-pour-la-production-connectee-au-reseau\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.orteanext.com\/fr\/transformateurs-et-reacteurs-bt\/reactance-limitatrice-de-courant-moyenne-tension-la-solution-sur-mesure-dortea-pour-la-production-connectee-au-reseau\/#primaryimage","url":"https:\/\/www.orteanext.com\/wp-content\/uploads\/2025\/12\/P50evd.jpg","contentUrl":"https:\/\/www.orteanext.com\/wp-content\/uploads\/2025\/12\/P50evd.jpg","width":800,"height":580},{"@type":"BreadcrumbList","@id":"https:\/\/www.orteanext.com\/fr\/transformateurs-et-reacteurs-bt\/reactance-limitatrice-de-courant-moyenne-tension-la-solution-sur-mesure-dortea-pour-la-production-connectee-au-reseau\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.orteanext.com\/fr\/"},{"@type":"ListItem","position":2,"name":"Transformateurs et r\u00e9acteurs","item":"https:\/\/www.orteanext.com\/fr\/cat\/transformateurs-et-reacteurs-bt\/"},{"@type":"ListItem","position":3,"name":"R\u00c9ACTANCE LIMITATRICE DE COURANT MOYENNE TENSION : LA SOLUTION SUR MESURE D\u2019ORTEA POUR LA PRODUCTION CONNECT\u00c9E AU R\u00c9SEAU"}]},{"@type":"WebSite","@id":"https:\/\/www.orteanext.com\/fr\/#website","url":"https:\/\/www.orteanext.com\/fr\/","name":"Ortea Next","description":"","publisher":{"@id":"https:\/\/www.orteanext.com\/fr\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.orteanext.com\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/www.orteanext.com\/fr\/#organization","name":"Ortea SpA","url":"https:\/\/www.orteanext.com\/fr\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.orteanext.com\/fr\/#\/schema\/logo\/image\/","url":"https:\/\/www.orteanext.com\/wp-content\/uploads\/2022\/05\/logo_ortea.svg","contentUrl":"https:\/\/www.orteanext.com\/wp-content\/uploads\/2022\/05\/logo_ortea.svg","width":1,"height":1,"caption":"Ortea SpA"},"image":{"@id":"https:\/\/www.orteanext.com\/fr\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/ortea\/","https:\/\/www.youtube.com\/channel\/UCqwcSga4ZzG3ntf6hYRu_Nw?reload=9"]},{"@type":"Person","@id":"https:\/\/www.orteanext.com\/fr\/#\/schema\/person\/fad56b88aae6c39db6d72d033199b714","name":"Pietro Cereda","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/secure.gravatar.com\/avatar\/be648c51974652a1c39aa0ed2ef0f3d777b546eda44f9d5eb9c82ed8226bcf84?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/be648c51974652a1c39aa0ed2ef0f3d777b546eda44f9d5eb9c82ed8226bcf84?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/be648c51974652a1c39aa0ed2ef0f3d777b546eda44f9d5eb9c82ed8226bcf84?s=96&d=mm&r=g","caption":"Pietro Cereda"}}]}},"_links":{"self":[{"href":"https:\/\/www.orteanext.com\/fr\/wp-json\/wp\/v2\/posts\/26710","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.orteanext.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.orteanext.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.orteanext.com\/fr\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.orteanext.com\/fr\/wp-json\/wp\/v2\/comments?post=26710"}],"version-history":[{"count":4,"href":"https:\/\/www.orteanext.com\/fr\/wp-json\/wp\/v2\/posts\/26710\/revisions"}],"predecessor-version":[{"id":30377,"href":"https:\/\/www.orteanext.com\/fr\/wp-json\/wp\/v2\/posts\/26710\/revisions\/30377"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.orteanext.com\/fr\/wp-json\/wp\/v2\/media\/26711"}],"wp:attachment":[{"href":"https:\/\/www.orteanext.com\/fr\/wp-json\/wp\/v2\/media?parent=26710"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.orteanext.com\/fr\/wp-json\/wp\/v2\/categories?post=26710"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.orteanext.com\/fr\/wp-json\/wp\/v2\/tags?post=26710"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}