{"id":28392,"date":"2026-04-14T09:39:00","date_gmt":"2026-04-14T07:39:00","guid":{"rendered":"https:\/\/www.orteanext.com\/nouvelles\/energy-intensive-companies-where-power-quality-really-makes-the-difference\/"},"modified":"2026-04-14T09:56:19","modified_gmt":"2026-04-14T07:56:19","slug":"entreprises-energivores-la-ou-la-qualite-de-lenergie-fait-vraiment-la-difference","status":"publish","type":"post","link":"https:\/\/www.orteanext.com\/fr\/qualite-de-l-energie\/entreprises-energivores-la-ou-la-qualite-de-lenergie-fait-vraiment-la-difference\/","title":{"rendered":"ENTREPRISES \u00c9NERGIVORES : L\u00c0 O\u00d9 LA QUALIT\u00c9 DE L\u2019\u00c9NERGIE FAIT (VRAIMENT) LA DIFF\u00c9RENCE"},"content":{"rendered":"<p>\u00c0 06 h 45, la ligne d\u2019extrusion est d\u00e9j\u00e0 \u00e0 temp\u00e9rature. Un creux de tension de quelques millisecondes suffit \u00e0 faire perdre la synchronisation \u00e0 un variateur ; l\u2019API passe en d\u00e9faut et la supervision affiche \u00ab arr\u00eat de s\u00e9curit\u00e9 \u00bb. Dans le local \u00e9lectrique, personne n\u2019a vu de v\u00e9ritable coupure &#8211; et pourtant l\u2019\u00e9quipe s\u2019arr\u00eate, le plastique refroidit dans la fili\u00e8re et il faut reprendre la mati\u00e8re.<\/p>\n<p>C\u2019est un <strong>creux de tension (sag)<\/strong> : \u00e7a dure peu, mais \u00e7a co\u00fbte cher.<\/p>\n<p>\u00c0 l\u2019autre bout de l\u2019usine, l\u2019\u00e9clairage LED scintille l\u00e9g\u00e8rement : ce n\u2019est pas dramatique, mais c\u2019est le signe que les <strong>harmoniques<\/strong> et une <strong>tension \u00ab trop \u00e9lev\u00e9e<\/strong> \u00bb font travailler l\u2019ensemble au-dessus du point optimal. Pendant ce temps, la facture affiche une ligne constante de <strong>p\u00e9nalit\u00e9s cos<\/strong><strong>\u03c6<\/strong>.<\/p>\n<h3><strong>C\u2019est ici, dans la somme des d\u00e9tails \u00e9lectriques et des temps homme-machine, que la qualit\u00e9 de l\u2019\u00e9nergie impacte l\u2019OPEX et la productivit\u00e9.<\/strong><\/h3>\n<p><strong>\u00a0<\/strong><\/p>\n<h2><strong>COMMENT LE PROBL\u00c8ME SE MANIFESTE<\/strong><\/h2>\n<h3><strong>LIGNE D\u2019EMBOUTEILLAGE \u00c0 HAUTE CADENCE<\/strong><\/h3>\n<p>Un <strong>creux de tension<\/strong> pendant la phase de pick-and-place suffit \u00e0 d\u00e9clencher une cascade d\u2019alarmes : variateurs en protection, codeurs qui perdent leur r\u00e9f\u00e9rence, syst\u00e8mes de vision qui red\u00e9marrent. La ligne repart, mais le lot tout juste \u00e9tiquet\u00e9 part au rebut car non conforme. Un <strong>compensateur de creux<\/strong> install\u00e9 en aval du poste, r\u00e9gl\u00e9 pour intervenir <strong>en quelques millisecondes<\/strong>, permet de \u00ab franchir \u00bb l\u2019\u00e9v\u00e9nement sans qu\u2019il n\u2019atteigne la logique de commande. (Gamme <strong>Oxygen<\/strong>, r\u00e9ponse <strong>&lt;3 ms<\/strong>, jusqu\u2019\u00e0 <strong>2500 kVA<\/strong> ; pour des <strong>microcoupures<\/strong> r\u00e9p\u00e9t\u00e9es, <strong>Oxygen Zero<\/strong> avec <strong>supercondensateurs<\/strong>, <strong>&lt;5 ms<\/strong>, <strong>500-1500 kVA<\/strong>).<\/p>\n<h3><strong>ATELIER EXTRUSION \/ INJECTION<\/strong><\/h3>\n<p>La formulation est parfaite, mais la <strong>tension r\u00e9elle<\/strong> en bout de ligne est plus \u00e9lev\u00e9e que n\u00e9cessaire. Moteurs et r\u00e9sistances chauffent au-del\u00e0 du besoin, les kWh augmentent, l\u2019\u00e9lectronique fonctionne \u00ab sous contrainte \u00bb.<\/p>\n<p>Un syst\u00e8me d\u2019<strong>optimisation dynamique de la tension<\/strong> ram\u00e8ne l\u2019alimentation dans la <strong>fen\u00eatre d\u2019efficacit\u00e9<\/strong> des charges : baisse de la consommation, des pics thermiques et des d\u00e9fauts, avec <strong>supervision cloud<\/strong> pour mesurer l\u2019avant\/apr\u00e8s. (Solutions <strong>Enersolve<\/strong> et <strong>ComEC<\/strong>, avec des \u00e9conomies <strong>jusqu\u2019\u00e0 ~12 %<\/strong> dans les sc\u00e9narios adapt\u00e9s.)<\/p>\n<h3><strong>PAPIER \/ TEXTILE AVEC VARIATEURS TR\u00c8S PR\u00c9SENTS<\/strong><\/h3>\n<p>La productivit\u00e9 baisse \u00ab \u00e0 chaud \u00bb : transformateurs et tableaux BT sont plus ti\u00e8des que d\u2019habitude, certaines protections d\u00e9clenchent sans d\u00e9faut \u00e9vident. Ici, les harmoniques dues aux charges non lin\u00e9aires sont en cause : le courant est \u00ab pollu\u00e9 \u00bb, il g\u00e9n\u00e8re des pertes, \u00e9chauffe les composants et perturbe les protections.<\/p>\n<p>Un <strong>filtre actif<\/strong> annule la distorsion en temps r\u00e9el en s\u2019adaptant au profil des charges (<strong>ACTIVEmatic FA40, 60-300 A<\/strong>), et le tableau redevient \u00ab froid \u00bb.<\/p>\n<h3><strong>FOURS, COMPRESSEURS, POMPES (LA QUESTION DU COS<\/strong><strong>\u03c6<\/strong><strong>)<\/strong><\/h3>\n<p>\u00c0 chaque \u00e9quipe, la m\u00eame surprise : <strong>p\u00e9nalit\u00e9s<\/strong> sur la facture et impression d\u2019un r\u00e9seau \u00ab satur\u00e9 \u00bb sans nouveaux r\u00e9cepteurs. Le <strong>compensation d\u2019\u00e9nergie r\u00e9active<\/strong> (correction du facteur de puissance) lib\u00e8re de la capacit\u00e9, d\u00e9sature les lignes et met fin aux p\u00e9nalit\u00e9s ; avec un THD mod\u00e9r\u00e9, des syst\u00e8mes BT de la gamme <strong>HP10\/20\/30<\/strong> suffisent ; avec un contenu harmonique \u00e9lev\u00e9, il faut des \u00e9quipements <strong>FH20\/30\/40<\/strong> avec selfs de d\u00e9saccord pour \u00e9viter les r\u00e9sonances.<\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<h2><strong>CE QUI CHANGE QUAND ON INTERVIENT (AVEC M\u00c9THODE)<\/strong><\/h2>\n<p>Il ne s\u2019agit pas \u00ab d\u2019acheter une bo\u00eete \u00bb, mais d\u2019ing\u00e9nierie : <strong>concevoir une architecture<\/strong> coh\u00e9rente avec l\u2019installation et le process. Dans les sites avec un r\u00e9seau faible ou variable, un <strong>stabilisateur de tension<\/strong> en amont maintient la valeur proche du nominal (familles robustes <strong>Orion\/Orion Plus 2-2000 kVA<\/strong> et <strong>Sirius\/Sirius Advance 60-6000 kVA<\/strong> pour des r\u00e9seaux industriels complexes ; <strong>Aquarius\/Odyssey<\/strong> couvrent les cas o\u00f9 la rapidit\u00e9 d\u2019intervention est d\u00e9terminante) et, si n\u00e9cessaire, des <strong>compensateurs<\/strong> absorbent les \u00e9v\u00e9nements rapides avant qu\u2019ils n\u2019atteignent API et variateurs. En aval, <strong>filtres actifs<\/strong> et c<strong>ompensation r\u00e9active<\/strong> nettoient et soulagent le r\u00e9seau.<\/p>\n<p>R\u00e9sultat : la <strong>logique de commande ne confond plus les perturbations avec des pannes<\/strong>, les cycles ne s\u2019interrompent plus, et les composants travaillent dans leur zone de dur\u00e9e de vie maximale.<\/p>\n<p>Dans de nombreuses entreprises \u00e9nergivores, la combinaison gagnante est : <strong>stabilisation\/optimisation de tension<\/strong> \u2192 <strong>compensation des \u00e9v\u00e9nements rapides<\/strong> sur les lignes sensibles \u2192 <strong>filtrage harmonique<\/strong> \u2192 <strong>correction du facteur de puissance<\/strong>. L\u2019ordre compte, car chaque bloc prot\u00e8ge &#8211; et rend plus efficace &#8211; le suivant.<\/p>\n<h2><strong>COMMENT CONCR\u00c9TISER UN PROJET (\u00c9TAPES PRATIQUES, AVEC EXEMPLES)<\/strong><\/h2>\n<ol>\n<li><strong>Instrumentation et baseline (7\u201314 jours).<\/strong><br \/>\nPose d\u2019enregistreurs au poste, au MCC et sur les lignes critiques. Acquisition des tensions par phase, THD courant\/tension, \u00e9v\u00e9nements rapides (ms) et d\u00e9s\u00e9quilibres, en corr\u00e9lant chaque anomalie aux arr\u00eats, rebuts et p\u00e9nalit\u00e9s. Dans une entreprise agroalimentaire, le suivi a montr\u00e9 que des arr\u00eats \u00ab myst\u00e9rieux \u00bb co\u00efncidaient avec des creux de 100\u2013200 ms lors du d\u00e9marrage des compresseurs frigorifiques : la donn\u00e9e a justifi\u00e9 l\u2019installation d\u2019Oxygen pour prot\u00e9ger la dorsale froid.<\/li>\n<li><strong>Analyse des \u00ab co\u00fbts invisibles \u00bb.<\/strong><br \/>\nLe co\u00fbt r\u00e9el d\u2019une mauvaise qualit\u00e9 de l\u2019\u00e9nergie peut \u00eatre estim\u00e9 ainsi :<\/li>\n<\/ol>\n<p><strong>Co\u00fbt invisible = Arr\u00eats \u00d7 Co\u00fbt\/min + Rebuts + P\u00e9nalit\u00e9s cos<\/strong><strong>\u03c6<\/strong><strong> + (kWh en plus \u00d7 \u20ac\/kWh)<\/strong><\/p>\n<ul>\n<li><strong>Arr\u00eats<\/strong> : minutes d\u2019arr\u00eat de l\u2019installation<\/li>\n<li><strong>Co\u00fbt\/min<\/strong> : perte \u00e9conomique par minute (production perdue, personnel, \u00e9nergie)<\/li>\n<li><strong>Rebuts<\/strong> : pi\u00e8ces \u00e0 jeter ou \u00e0 retoucher<\/li>\n<li><strong>P\u00e9nalit\u00e9s cos<\/strong><strong>\u03c6<\/strong> : surco\u00fbts sur facture<\/li>\n<li><strong>kWh en plus<\/strong> : consommation additionnelle due \u00e0 surtension\/harmoniques<\/li>\n<\/ul>\n<p><strong>Exemple pratique<\/strong><br \/>\nSur une <strong>presse de 900 tonnes<\/strong> :<\/p>\n<ul>\n<li>6 arr\u00eats\/mois<\/li>\n<li>Dur\u00e9e moyenne : 12 minutes<\/li>\n<li>Co\u00fbt : 250 \u20ac\/minute<\/li>\n<\/ul>\n<p>Calcul :<br \/>\n6 \u00d7 12 \u00d7 250 = <strong>18 000 \u20ac\/mois<\/strong> de co\u00fbt d\u2019exploitation rien que pour les arr\u00eats.<\/p>\n<p>Avec des solutions qui <strong>pr\u00e9viennent les \u00e9v\u00e9nements rapides<\/strong>, ce poste diminue fortement. Le <strong>surveillance dans le cloud <\/strong>certifie l\u2019avant\/apr\u00e8s et rend ces co\u00fbts visibles et mesurables.<\/p>\n<ol start=\"3\">\n<li><strong>Conception et priorit\u00e9s<\/strong>.<br \/>\nSi la <strong>tension<\/strong> est syst\u00e9matiquement trop \u00e9lev\u00e9e ou fluctuante, on commence par <strong>stabilisation\/optimisation<\/strong> ; si les creux sont fr\u00e9quents, on prot\u00e8ge les dorsales avec <strong>Oxygen<\/strong> ; avec un <strong>THD<\/strong> \u00e9lev\u00e9, on dimensionne un <strong>filtre actif<\/strong> et on adapte la compensation (HP ou FH). Les gammes et plages de <strong>puissance\/courant<\/strong> couvrent des installations moyennes jusqu\u2019aux sites \u00e9nergivores complexes ; le <strong>r\u00e9seau mondial<\/strong> et les <strong>services<\/strong> (ing\u00e9nierie, mise en service, maintenance) permettent des d\u00e9ploiements scalables.<\/li>\n<li><strong>PoC et d\u00e9ploiement<\/strong>.<br \/>\nUn pilote sur une ligne sensible (embouteillage, coupe papier, bobinage) mesure le delta d\u2019OEE, les kWh \u00e9vit\u00e9s et la r\u00e9duction des pannes ; si les chiffres sont concluants, on d\u00e9ploie par atelier. Avec<strong> XCloud<\/strong>, l\u2019\u00e9volution reste suivie dans le temps (param\u00e8tres, alarmes thermiques, tendances THD\/d\u00e9s\u00e9quilibres) et on planifie la <strong>maintenance pr\u00e9ventive<\/strong>.<\/li>\n<\/ol>\n<p>&nbsp;<\/p>\n<h2><strong>SC\u00c9NARIOS TYPIQUES ET SOLUTIONS<\/strong><\/h2>\n<ul>\n<li>Un <strong>creux de tension pendant la phase de take-out en injection<\/strong> : sans protection, la pince s\u2019arr\u00eate \u00e0 mi-course, l\u2019extrudeuse accumule de la mati\u00e8re et l\u2019empreinte se d\u00e9grade ; avec Oxygen (&lt;3 ms), l\u2019automatisme ne \u00ab voit \u00bb pas l\u2019\u00e9v\u00e9nement et le cycle se termine normalement.<\/li>\n<li><strong>Pics thermiques anormaux en tableaux BT<\/strong> : souvent un <strong>THD de courant<\/strong> ; un <strong>filtre actif FA40<\/strong> r\u00e9duit la distorsion, baisse les pertes et stabilise des protections \u00ab nerveuses \u00bb.<\/li>\n<li><strong>P\u00e9nalit\u00e9s r\u00e9currentes avec un r\u00e9seau d\u00e9j\u00e0 \u00ab tir\u00e9 \u00bb<\/strong> : la <strong>compensation<\/strong> (HP\/FH) lib\u00e8re de la capacit\u00e9, r\u00e9duit les pertes I\u00b2R et stabilise la tension en aval, permettant de nouvelles charges sans refaire la dorsale.<\/li>\n<li><strong>Site multi-lignes avec tension r\u00e9elle &gt; nominale<\/strong> : un <strong>Enersolve<\/strong> en t\u00eate ram\u00e8ne la tension dans la fen\u00eatre efficiente ; sur les dorsales sensibles on ajoute <strong>Oxygen Zero<\/strong> pour les microcoupures. Les \u00e9conomies restent \u00ab r\u00e9elles \u00bb car elles ne se paient pas en arr\u00eats.<\/li>\n<\/ul>\n<p><strong>\u00a0<\/strong><\/p>\n<h2><strong>CE QUE VOUS MESUREZ<\/strong><\/h2>\n<p>Un simple \u00ab on consomme moins \u00bb ne suffit pas. La baseline et le cloud permettent des chiffres <strong>d\u00e9fendables<\/strong> :<\/p>\n<ul>\n<li><strong>kWh \u00e9vit\u00e9s<\/strong> via optimisation\/stabilisation ;<\/li>\n<li><strong>arr\u00eats\/rebuts \u00e9vit\u00e9s<\/strong> gr\u00e2ce \u00e0 Oxygen\/Zero (horodatage corr\u00e9l\u00e9 aux \u00e9v\u00e9nements) ;<\/li>\n<li><strong>p\u00e9nalit\u00e9s supprim\u00e9es<\/strong> par la correction du cos\u03c6 ;<\/li>\n<li><strong>THD<\/strong> avant\/apr\u00e8s avec filtrage.<\/li>\n<\/ul>\n<p>Exemple prudent : sur 4,5 GWh\/an \u00e0 0,17 \u20ac\/kWh, une <strong>r\u00e9duction de 6 % <\/strong>via optimisation vaut <strong>270 MWh\/an = 45 900 \u20ac\/an <\/strong>; avec <strong>8 000 \u20ac\/an<\/strong> de p\u00e9nalit\u00e9s cos\u03c6 supprim\u00e9es, un <strong>capex de 100 k\u20ac<\/strong> se rembourse en environ <strong>1,9 an<\/strong>. Le meilleur ? Tout est document\u00e9, du synoptique aux rapports exportables pour aides et audits.<\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<h2><strong>SOLUTIONS ORTEA NEXT AVEC CONTEXTE D\u2019USAGE<\/strong><\/h2>\n<ul>\n<li><strong>Stabilisateurs \u00e9lectrom\u00e9caniques<\/strong> <strong><a href=\"https:\/\/www.orteanext.com\/fr\/produit\/orion\/\">Orion<\/a>\/<a href=\"https:\/\/www.orteanext.com\/fr\/produit\/sirius\/\">Sirius<\/a> (2-6000 kVA)<\/strong> : r\u00e9seaux industriels complexes, robustesse et continuit\u00e9 sur grands sites. <strong>Stabilisateurs statiques <a href=\"https:\/\/www.orteanext.com\/fr\/produit\/aquarius\/\">Aquarius<\/a>\/<a href=\"https:\/\/www.orteanext.com\/fr\/produit\/odyssey\/\">Odyssey<\/a> (10-4000 kVA)<\/strong> : r\u00e9ponse rapide, environnements critiques (sant\u00e9, data centers).<\/li>\n<li><strong><a href=\"https:\/\/www.orteanext.com\/fr\/produits\/compensateurs-de-creux-de-tension\/\">Oxygen<\/a> \/ <a href=\"https:\/\/www.orteanext.com\/fr\/produits\/compensaterus-de-microcoupures\/\">Oxygen Zero<\/a><\/strong> : creux et microcoupures neutralis\u00e9s <strong>en 3\u20135 ms<\/strong>, jusqu\u2019\u00e0 <strong>2500 kVA<\/strong> ; id\u00e9al sur lignes API\/variateurs o\u00f9 200 ms valent des milliers d\u2019euros.<\/li>\n<li><strong><a href=\"https:\/\/www.orteanext.com\/fr\/produit\/fa40\/\">Filtres actifs FA40<\/a> (60\u2013300 A<\/strong>) : r\u00e9duisent la distorsion harmonique en temps r\u00e9el avec des charges non lin\u00e9aires.<\/li>\n<li><strong><a href=\"https:\/\/www.orteanext.com\/fr\/produits\/systemes-de-correction-du-facteur-de-puissance-a-basse-tension\/\">Compensation HP\/FH BT<\/a> et <a href=\"https:\/\/www.orteanext.com\/fr\/produits\/systemes-de-correction-du-facteur-de-puissance-en-moyenne-tension\/\">tableaux MT<\/a><\/strong> : suppriment les p\u00e9nalit\u00e9s et lib\u00e8rent de la capacit\u00e9 m\u00eame en THD \u00e9lev\u00e9.<\/li>\n<li><strong><a href=\"https:\/\/www.orteanext.com\/fr\/produits\/efficacite-energetique-dispositifs-intelligents\/\">Enersolve<\/a> \/ <a href=\"https:\/\/www.orteanext.com\/fr\/produits\/sion-pour-les-economies-denergie-dans-le-retail\/\">ComEC<\/a><\/strong> : optimisation dynamique de tension avec surveillance dans le cloud<\/li>\n<\/ul>\n<p>;ComEC permet <strong>jusqu\u2019\u00e0 ~12 %<\/strong> d\u2019\u00e9conomies avec des charges stables.<\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<h2><strong>TROIS V\u00c9RIFICATIONS SIMPLES (MA R\u00c9V\u00c9LATRICES)<\/strong><\/h2>\n<ol>\n<li><strong>Demandez au maintenance<\/strong> quand apparaissent les d\u00e9fauts les plus g\u00eanants : souvent ils \u00ab co\u00efncident \u00bb avec le d\u00e9marrage de gros moteurs ou des orages.<\/li>\n<li><strong>Contr\u00f4lez <\/strong>(<strong>cam\u00e9ra thermique<\/strong>) transformateurs et tableaux aux heures de pointe : s\u2019ils \u00ab chauffent \u00bb, c\u2019est un signal de THD ou de surtension.<\/li>\n<li><strong>Regardez la facture<\/strong> : la ligne de <strong>p\u00e9nalit\u00e9s cos<\/strong><strong>\u03c6<\/strong> en dit long sur l\u2019\u00e9tat r\u00e9el du r\u00e9seau.<\/li>\n<\/ol>\n<p>Les trois m\u00e8nent au m\u00eame point : <strong>mesurer<\/strong> et <strong>intervenir<\/strong> l\u00e0 o\u00f9 c\u2019est n\u00e9cessaire, dans le bon ordre.<\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<h2><strong>POURQUOI ORTEA NEXT<\/strong><\/h2>\n<p>Portefeuille <strong>int\u00e9gr\u00e9<\/strong> (stabilisation, compensation d\u2019\u00e9v\u00e9nements rapides, correction du facteur de puissance, filtres, optimisation, transformateurs), <strong>ing\u00e9nierie syst\u00e8me<\/strong> et <strong>services<\/strong> de bout en bout : de la collecte des besoins \u00e0 la maintenance pr\u00e9ventive, avec <strong>t\u00e9l\u00e9surveillance<\/strong> (<strong>XCloud<\/strong>) et pr\u00e9sence dans plus de <strong>100 pays<\/strong>. Cela signifie des solutions sur mesure et des <strong>d\u00e9ploiements<\/strong> fiables, m\u00eame multi-sites.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u00c0 06 h 45, la ligne d\u2019extrusion est d\u00e9j\u00e0 \u00e0 temp\u00e9rature. Un creux de tension de quelques millisecondes suffit \u00e0 faire perdre la synchronisation \u00e0 un variateur ; l\u2019API passe en d\u00e9faut et la supervision affiche \u00ab arr\u00eat de s\u00e9curit\u00e9 \u00bb. Dans le local \u00e9lectrique, personne n\u2019a vu de v\u00e9ritable coupure &#8211; et pourtant l\u2019\u00e9quipe [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":28394,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":""},"categories":[13045,20096],"tags":[],"class_list":["post-28392","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-power-quality-en","category-qualite-de-l-energie"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Entreprises \u00e9nergivores : comment am\u00e9liorer la qualit\u00e9 de l\u2019\u00e9nergie<\/title>\n<meta name=\"description\" content=\"Creux de tension, microcoupures, harmoniques, fluctuations de tension et cos\u03c6 faible g\u00e9n\u00e8rent arr\u00eats et gaspillage. Probl\u00e8mes et solutions.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.orteanext.com\/fr\/qualite-de-l-energie\/entreprises-energivores-la-ou-la-qualite-de-lenergie-fait-vraiment-la-difference\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Entreprises \u00e9nergivores : comment am\u00e9liorer la qualit\u00e9 de l\u2019\u00e9nergie\" \/>\n<meta property=\"og:description\" content=\"Creux de tension, microcoupures, harmoniques, fluctuations de tension et cos\u03c6 faible g\u00e9n\u00e8rent arr\u00eats et gaspillage. Probl\u00e8mes et solutions.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.orteanext.com\/fr\/qualite-de-l-energie\/entreprises-energivores-la-ou-la-qualite-de-lenergie-fait-vraiment-la-difference\/\" \/>\n<meta property=\"og:site_name\" content=\"Ortea Next\" \/>\n<meta property=\"article:published_time\" content=\"2026-04-14T07:39:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-14T07:56:19+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.orteanext.com\/wp-content\/uploads\/2026\/04\/26P17evd.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"580\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Pietro Cereda\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"Pietro Cereda\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"8 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/qualite-de-l-energie\\\/entreprises-energivores-la-ou-la-qualite-de-lenergie-fait-vraiment-la-difference\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/qualite-de-l-energie\\\/entreprises-energivores-la-ou-la-qualite-de-lenergie-fait-vraiment-la-difference\\\/\"},\"author\":{\"name\":\"Pietro Cereda\",\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/#\\\/schema\\\/person\\\/fad56b88aae6c39db6d72d033199b714\"},\"headline\":\"ENTREPRISES \u00c9NERGIVORES : L\u00c0 O\u00d9 LA QUALIT\u00c9 DE L\u2019\u00c9NERGIE FAIT (VRAIMENT) LA DIFF\u00c9RENCE\",\"datePublished\":\"2026-04-14T07:39:00+00:00\",\"dateModified\":\"2026-04-14T07:56:19+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/qualite-de-l-energie\\\/entreprises-energivores-la-ou-la-qualite-de-lenergie-fait-vraiment-la-difference\\\/\"},\"wordCount\":1720,\"publisher\":{\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/qualite-de-l-energie\\\/entreprises-energivores-la-ou-la-qualite-de-lenergie-fait-vraiment-la-difference\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.orteanext.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/26P17evd.jpg\",\"articleSection\":[\"Power Quality\",\"Qualit\u00e9 de l'\u00e9nergie\"],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/qualite-de-l-energie\\\/entreprises-energivores-la-ou-la-qualite-de-lenergie-fait-vraiment-la-difference\\\/\",\"url\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/qualite-de-l-energie\\\/entreprises-energivores-la-ou-la-qualite-de-lenergie-fait-vraiment-la-difference\\\/\",\"name\":\"Entreprises \u00e9nergivores : comment am\u00e9liorer la qualit\u00e9 de l\u2019\u00e9nergie\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/qualite-de-l-energie\\\/entreprises-energivores-la-ou-la-qualite-de-lenergie-fait-vraiment-la-difference\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/qualite-de-l-energie\\\/entreprises-energivores-la-ou-la-qualite-de-lenergie-fait-vraiment-la-difference\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.orteanext.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/26P17evd.jpg\",\"datePublished\":\"2026-04-14T07:39:00+00:00\",\"dateModified\":\"2026-04-14T07:56:19+00:00\",\"description\":\"Creux de tension, microcoupures, harmoniques, fluctuations de tension et cos\u03c6 faible g\u00e9n\u00e8rent arr\u00eats et gaspillage. Probl\u00e8mes et solutions.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/qualite-de-l-energie\\\/entreprises-energivores-la-ou-la-qualite-de-lenergie-fait-vraiment-la-difference\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/qualite-de-l-energie\\\/entreprises-energivores-la-ou-la-qualite-de-lenergie-fait-vraiment-la-difference\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/qualite-de-l-energie\\\/entreprises-energivores-la-ou-la-qualite-de-lenergie-fait-vraiment-la-difference\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.orteanext.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/26P17evd.jpg\",\"contentUrl\":\"https:\\\/\\\/www.orteanext.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/26P17evd.jpg\",\"width\":800,\"height\":580},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/qualite-de-l-energie\\\/entreprises-energivores-la-ou-la-qualite-de-lenergie-fait-vraiment-la-difference\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Qualit\u00e9 de l'\u00e9nergie\",\"item\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/cat\\\/qualite-de-l-energie\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"ENTREPRISES \u00c9NERGIVORES : L\u00c0 O\u00d9 LA QUALIT\u00c9 DE L\u2019\u00c9NERGIE FAIT (VRAIMENT) LA DIFF\u00c9RENCE\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/#website\",\"url\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/\",\"name\":\"Ortea Next\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/#organization\",\"name\":\"Ortea SpA\",\"url\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.orteanext.com\\\/wp-content\\\/uploads\\\/2022\\\/05\\\/logo_ortea.svg\",\"contentUrl\":\"https:\\\/\\\/www.orteanext.com\\\/wp-content\\\/uploads\\\/2022\\\/05\\\/logo_ortea.svg\",\"width\":1,\"height\":1,\"caption\":\"Ortea SpA\"},\"image\":{\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/ortea\\\/\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCqwcSga4ZzG3ntf6hYRu_Nw?reload=9\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.orteanext.com\\\/fr\\\/#\\\/schema\\\/person\\\/fad56b88aae6c39db6d72d033199b714\",\"name\":\"Pietro Cereda\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/be648c51974652a1c39aa0ed2ef0f3d777b546eda44f9d5eb9c82ed8226bcf84?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/be648c51974652a1c39aa0ed2ef0f3d777b546eda44f9d5eb9c82ed8226bcf84?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/be648c51974652a1c39aa0ed2ef0f3d777b546eda44f9d5eb9c82ed8226bcf84?s=96&d=mm&r=g\",\"caption\":\"Pietro Cereda\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Entreprises \u00e9nergivores : comment am\u00e9liorer la qualit\u00e9 de l\u2019\u00e9nergie","description":"Creux de tension, microcoupures, harmoniques, fluctuations de tension et cos\u03c6 faible g\u00e9n\u00e8rent arr\u00eats et gaspillage. Probl\u00e8mes et solutions.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.orteanext.com\/fr\/qualite-de-l-energie\/entreprises-energivores-la-ou-la-qualite-de-lenergie-fait-vraiment-la-difference\/","og_locale":"fr_FR","og_type":"article","og_title":"Entreprises \u00e9nergivores : comment am\u00e9liorer la qualit\u00e9 de l\u2019\u00e9nergie","og_description":"Creux de tension, microcoupures, harmoniques, fluctuations de tension et cos\u03c6 faible g\u00e9n\u00e8rent arr\u00eats et gaspillage. Probl\u00e8mes et solutions.","og_url":"https:\/\/www.orteanext.com\/fr\/qualite-de-l-energie\/entreprises-energivores-la-ou-la-qualite-de-lenergie-fait-vraiment-la-difference\/","og_site_name":"Ortea Next","article_published_time":"2026-04-14T07:39:00+00:00","article_modified_time":"2026-04-14T07:56:19+00:00","og_image":[{"width":800,"height":580,"url":"https:\/\/www.orteanext.com\/wp-content\/uploads\/2026\/04\/26P17evd.jpg","type":"image\/jpeg"}],"author":"Pietro Cereda","twitter_card":"summary_large_image","twitter_misc":{"\u00c9crit par":"Pietro Cereda","Dur\u00e9e de lecture estim\u00e9e":"8 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.orteanext.com\/fr\/qualite-de-l-energie\/entreprises-energivores-la-ou-la-qualite-de-lenergie-fait-vraiment-la-difference\/#article","isPartOf":{"@id":"https:\/\/www.orteanext.com\/fr\/qualite-de-l-energie\/entreprises-energivores-la-ou-la-qualite-de-lenergie-fait-vraiment-la-difference\/"},"author":{"name":"Pietro Cereda","@id":"https:\/\/www.orteanext.com\/fr\/#\/schema\/person\/fad56b88aae6c39db6d72d033199b714"},"headline":"ENTREPRISES \u00c9NERGIVORES : L\u00c0 O\u00d9 LA QUALIT\u00c9 DE L\u2019\u00c9NERGIE FAIT (VRAIMENT) LA DIFF\u00c9RENCE","datePublished":"2026-04-14T07:39:00+00:00","dateModified":"2026-04-14T07:56:19+00:00","mainEntityOfPage":{"@id":"https:\/\/www.orteanext.com\/fr\/qualite-de-l-energie\/entreprises-energivores-la-ou-la-qualite-de-lenergie-fait-vraiment-la-difference\/"},"wordCount":1720,"publisher":{"@id":"https:\/\/www.orteanext.com\/fr\/#organization"},"image":{"@id":"https:\/\/www.orteanext.com\/fr\/qualite-de-l-energie\/entreprises-energivores-la-ou-la-qualite-de-lenergie-fait-vraiment-la-difference\/#primaryimage"},"thumbnailUrl":"https:\/\/www.orteanext.com\/wp-content\/uploads\/2026\/04\/26P17evd.jpg","articleSection":["Power Quality","Qualit\u00e9 de l'\u00e9nergie"],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/www.orteanext.com\/fr\/qualite-de-l-energie\/entreprises-energivores-la-ou-la-qualite-de-lenergie-fait-vraiment-la-difference\/","url":"https:\/\/www.orteanext.com\/fr\/qualite-de-l-energie\/entreprises-energivores-la-ou-la-qualite-de-lenergie-fait-vraiment-la-difference\/","name":"Entreprises \u00e9nergivores : comment am\u00e9liorer la qualit\u00e9 de l\u2019\u00e9nergie","isPartOf":{"@id":"https:\/\/www.orteanext.com\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.orteanext.com\/fr\/qualite-de-l-energie\/entreprises-energivores-la-ou-la-qualite-de-lenergie-fait-vraiment-la-difference\/#primaryimage"},"image":{"@id":"https:\/\/www.orteanext.com\/fr\/qualite-de-l-energie\/entreprises-energivores-la-ou-la-qualite-de-lenergie-fait-vraiment-la-difference\/#primaryimage"},"thumbnailUrl":"https:\/\/www.orteanext.com\/wp-content\/uploads\/2026\/04\/26P17evd.jpg","datePublished":"2026-04-14T07:39:00+00:00","dateModified":"2026-04-14T07:56:19+00:00","description":"Creux de tension, microcoupures, harmoniques, fluctuations de tension et cos\u03c6 faible g\u00e9n\u00e8rent arr\u00eats et gaspillage. Probl\u00e8mes et solutions.","breadcrumb":{"@id":"https:\/\/www.orteanext.com\/fr\/qualite-de-l-energie\/entreprises-energivores-la-ou-la-qualite-de-lenergie-fait-vraiment-la-difference\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.orteanext.com\/fr\/qualite-de-l-energie\/entreprises-energivores-la-ou-la-qualite-de-lenergie-fait-vraiment-la-difference\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.orteanext.com\/fr\/qualite-de-l-energie\/entreprises-energivores-la-ou-la-qualite-de-lenergie-fait-vraiment-la-difference\/#primaryimage","url":"https:\/\/www.orteanext.com\/wp-content\/uploads\/2026\/04\/26P17evd.jpg","contentUrl":"https:\/\/www.orteanext.com\/wp-content\/uploads\/2026\/04\/26P17evd.jpg","width":800,"height":580},{"@type":"BreadcrumbList","@id":"https:\/\/www.orteanext.com\/fr\/qualite-de-l-energie\/entreprises-energivores-la-ou-la-qualite-de-lenergie-fait-vraiment-la-difference\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.orteanext.com\/fr\/"},{"@type":"ListItem","position":2,"name":"Qualit\u00e9 de l'\u00e9nergie","item":"https:\/\/www.orteanext.com\/fr\/cat\/qualite-de-l-energie\/"},{"@type":"ListItem","position":3,"name":"ENTREPRISES \u00c9NERGIVORES : L\u00c0 O\u00d9 LA QUALIT\u00c9 DE L\u2019\u00c9NERGIE FAIT (VRAIMENT) LA DIFF\u00c9RENCE"}]},{"@type":"WebSite","@id":"https:\/\/www.orteanext.com\/fr\/#website","url":"https:\/\/www.orteanext.com\/fr\/","name":"Ortea Next","description":"","publisher":{"@id":"https:\/\/www.orteanext.com\/fr\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.orteanext.com\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/www.orteanext.com\/fr\/#organization","name":"Ortea SpA","url":"https:\/\/www.orteanext.com\/fr\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.orteanext.com\/fr\/#\/schema\/logo\/image\/","url":"https:\/\/www.orteanext.com\/wp-content\/uploads\/2022\/05\/logo_ortea.svg","contentUrl":"https:\/\/www.orteanext.com\/wp-content\/uploads\/2022\/05\/logo_ortea.svg","width":1,"height":1,"caption":"Ortea SpA"},"image":{"@id":"https:\/\/www.orteanext.com\/fr\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/ortea\/","https:\/\/www.youtube.com\/channel\/UCqwcSga4ZzG3ntf6hYRu_Nw?reload=9"]},{"@type":"Person","@id":"https:\/\/www.orteanext.com\/fr\/#\/schema\/person\/fad56b88aae6c39db6d72d033199b714","name":"Pietro Cereda","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/secure.gravatar.com\/avatar\/be648c51974652a1c39aa0ed2ef0f3d777b546eda44f9d5eb9c82ed8226bcf84?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/be648c51974652a1c39aa0ed2ef0f3d777b546eda44f9d5eb9c82ed8226bcf84?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/be648c51974652a1c39aa0ed2ef0f3d777b546eda44f9d5eb9c82ed8226bcf84?s=96&d=mm&r=g","caption":"Pietro Cereda"}}]}},"_links":{"self":[{"href":"https:\/\/www.orteanext.com\/fr\/wp-json\/wp\/v2\/posts\/28392","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.orteanext.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.orteanext.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.orteanext.com\/fr\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.orteanext.com\/fr\/wp-json\/wp\/v2\/comments?post=28392"}],"version-history":[{"count":3,"href":"https:\/\/www.orteanext.com\/fr\/wp-json\/wp\/v2\/posts\/28392\/revisions"}],"predecessor-version":[{"id":28397,"href":"https:\/\/www.orteanext.com\/fr\/wp-json\/wp\/v2\/posts\/28392\/revisions\/28397"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.orteanext.com\/fr\/wp-json\/wp\/v2\/media\/28394"}],"wp:attachment":[{"href":"https:\/\/www.orteanext.com\/fr\/wp-json\/wp\/v2\/media?parent=28392"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.orteanext.com\/fr\/wp-json\/wp\/v2\/categories?post=28392"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.orteanext.com\/fr\/wp-json\/wp\/v2\/tags?post=28392"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}