Technical specifications

Frequency
50Hz ±5%
Voltage regulation
IGBT + Supercapacitors
Selectable target voltage
400V
Output voltage accuracy
±0,5%
Admitted load variation
Up to 100%
Admitted load imbalance [%]
100
Cooling
Forced ventilation
Ambient temperature
0/+40°C
Storage temperature
0/+60°C
Max related humidity
<95% (non condensing)
Harmonic distorsion
Harmonic tolerance according to IEC 61000-2-4 Class 2 (THDV < 8%)
Colour
RAL 9005
Instrumentation
  • 10" touch panel, multilingual (on request remotely available by dedicated software connected to the same Ethernet network)
Installation
Indoor
Communication system
MODBUS TCP/IP
Overvoltage protection
  • Class II output surge arrestors
Additional protections
  • Input automatic circuit breaker
  • By-pass line with interlocked circuit breaker
  • Output interlocked automatic circuit breaker

Oxygen Zero K

type
efficiency
rated power
input voltage variation [%]
output voltage
correction time
Data Sheet
500K-1
>99
500
-100
400
<5 ms
1000K-1
>99
1000
-100
400
<5 ms
1500K-1
>99
1500
-100
400
<5 ms